Sterile Connecting Device
410210,Tata Memorial Center - Advanced Centre for Treatment, Research and Education in Cancer (ACTREC), Plt no.1 &2, Sector 22, Kharghar, Navi Mumbai
- Delivery
- 45 days
Specifications & requirements · 34
- Specification Name
- बड के िलए आवPयक अनुमत मूWय /Bid Requirement (Allowed Values)
- Product Description
- Sterile Connecting Device
- Specification Name
- बड के िलए आवPयक अनुमत मूWय /Bid Requirement (Allowed Values)
- Should be fully closed and sterile connection between tubing to enable transfer to fluid/blood from one bag/container to another by welding the tubes between them effectively as a closed system
- Yes
- Tubing Material
- Polyvinyl chloride(PVC)
- Heating Technology
- With Connecting Blade or Wafer
- Touch Screen Display Type
- LCD
- Visual Alarm to Indicate Errors/Malfunctions
- Yes
- Portability
- Yes
- Minimum Wafer Temperature During Operation
- 300.0 (degree Celsius)
- Should be compatible with all standard Tubing of blood bags
- Yes
- Tube Outer Diameter
- 4.5 (millimeter)
- Tube Inner Diameter
- 3.1 (millimeter)
- In-built sensor to monitor the temperature to ensure optimal quality and strength weld
- Yes
- Connection Type of Tube
- Wet-Dry
- Process Time (in second)
- 14-15
- Sterile welding of bags with shorter tube length
- Yes
- Mechanism for loading wager in to sterile connecting device
- Automatic
- Alignment for proper sterile sealing/docking of tubes
- Automatic
- Power Supply
- 220 -240 V, 50 Hz
- Additional Accessories
- AC power Cord, Fuses, Air Filter
- UPS Provided
- No
- Suitable Auto voltage corrector with spike protector should be available
- No
- Minimum Battery Back-up of UPS
- NA
- Compliance to Medical Device Rule (MDR) 2017 as amended till date
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूWय /Bid Requirement (Allowed Values)
- Availability of valid Medical device license/registration for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date
- Yes
- Manufacturing unit certification
- ISO: 13485 (Latest)
- Availability of Test Report for each supplied batch/product from CDSCO approved Laboratory as per Medical Device Rule (MDR) 2017 as amended till date
- Yes
- Electrical Safety Standards
- IEC/EN 60601-1 or equivalent BIS Standard
- Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement
- Yes
- Warranty
- 24, 36, 48, 60 Or higher (month)
- Minimum consumables (100 wafers/docks) to be provided at the time of installation free of cost
- 1) Minimum consumables (100 wafers/docks) to be provided at the time of installation free of cost - Yes
- Warranty
- 2) Warranty : 2 Years comprehensive-on site- factory warranty for the entire equipment system. All third party and bought out items, accessories, attachment, software etc. integrated with the system should also be covered by 2 years factory warranty from respective manufacturers. The vendor should perform 4 nos. of preventive maintenance services/ year, all breakdown visits and QA/QC as per prescribed protocol during the warranty period- Yes