Explosives / Narcotics Trace Detector
Delivery location700159,O/O DDG, ER NARCOTICS CONTROL BUREAU PREMISES No. 04-0321, PLOT No. DJ-2 STREET No. 321 POST OFFICE NEW TOWN ACTION AREA-III NEW TOWN RAJARHAT KOLKATA PIN CODE 700160
- Quantity
- 1 pieces
- Delivery
- 45 days
Delivery location600077,Narcotics Control Bureau, No. 49, 2nd Floor, FD- 2, II Main Road, III Avenue, TNHB layout, Ayyapakkam, , NCB Chennai Zonal Unit
- Quantity
- 1 pieces
- Delivery
- 45 days
Delivery location382421,Narcotics Control Bureau, Vaishno Devi Circle, Near Sardar Dham, Khodiyar, Ahmedabad
- Quantity
- 1 pieces
- Delivery
- 43 days
Delivery location781022,NARCOTICS CONTROL BUREAU, VIP ROAD RUPKONWAR PATH, CHACHAL, GUWAHATI PIN CODE 781022
- Quantity
- 1 pieces
- Delivery
- 45 days
Delivery location143001,B-181, B Block, Ranjit Avenue, Amritsar, Punjab
- Quantity
- 1 pieces
- Delivery
- 43 days
Delivery location400001,NARCOTICS CONTROL BUREAU, MUMBAI ZONAL UNIT, BALLARD ESTATE, MUMBAI PIN CODE 400001
- Quantity
- 1 pieces
- Delivery
- 45 days
Specifications & requirements · 49
- Specification Name
- बड के िलए आवPयक अनुमत मूXय /Bid Requirement (Allowed Values)
- Type
- Handheld
- Technology
- Raman Spectroscopy
- Detector Source - RadiationType
- Non-Radioactive
- Detection modes
- Both Explosives & Narcotics
- Sample collection/Acquisition
- Point and Shoot
- Each Sample collector uniquely bar coded
- No
- Number of Sample Collectors such as Swipe- Cards/Detector Cards/Surface Wipes/Sampling Swabs/Traps/Paper supplied
- NA
- Types of Explosives Detected
- Nitroaromatics (TNT, TNB, DNT, DNB, Tetryl), Nitramines (Pyrodex / Triple 8, Gunpowder, Nitroglycerin), Nitrate Esters (HMX, RDX, PETN, SEMTEX, EGDN, C4, NG, Smokeless Powders), Inorganic Nitrates (Ammonium Nitrate, Urea Nitrate, Potassium Nitrate), Chlorates (Sodium Chlorate, Potassium Chlorate), Peroxides (TATP, HMTD), Perchlorates, NA
- Types of Drugs/Narcotics Detected
- Methamphetamine, Cocaine, THC– Marijuana, Opiates, Synthetic Cannabinoids, Ketamine, Heroin, NA
- Analysis/Detection time
- 10 Or lower (second)
- Warm-up Time (Cold start) (Maximum)
- 0.25 (minute)
- Bakeout Time/Time betweenTwo Successive Tests(MINUTES)
- < 1
- Calibration
- Automatic
- Specification Name
- बड के िलए आवPयक अनुमत मूXय /Bid Requirement (Allowed Values)
- IP Protection
- IP 67
- Radiation Hazard during Testing
- No
- Availability of Radiation Safe Certificate
- NA
- Type of Display
- COLOR TFT
- Test result printing
- Through external printer
- If inbuilt printer, Type of printer
- N/A
- Supporting software for connecting to PC & Printer
- Yes
- In-built GPS
- No
- Memory (GB)
- 1
- Date/time Stamp in Entries
- Yes
- Connectivity interface
- USB
- Weight
- < 1000 g (for Handheld)
- Minimum Operating temperature
- -20 Or lower (degree Celsius)
- Maximum Operating temperature
- 60, 70 Or higher (degree Celsius)
- Operating humidity at 40 deg C
- 90.0 (percent)
- Warranty
- 1.0 (year)
- Conformity to Dust test as per
- NA
- Conformity to Vibration test as per
- MIL-STD-810 G
- Conformity to Shock test as per
- MIL-STD-810 G
- Conformity to Water Intrusion test as per
- NA
- Conformity to Conformity to Salt test as per
- NA
- Conformity to Rain test as per
- NA
- Conformity to Altitude test as per
- NA
- Specification Name
- बड के िलए आवPयक अनुमत मूXय /Bid Requirement (Allowed Values)
- Availability of Test Reports from Central Govt/NABL/ILAC acredited lab to prove confirmity to the Specifications
- Yes
- If Yes, Test Report to be furnished to the Buyer on demand
- Yes
- Comprehensive Maintenance ( Minimum Percentage )
- 3 %
- Comprehensive Maintenance ( Maximum Percentage )
- 25 %
- Warranty of required product
- 2 Year
- Comprehensive Maintenance Duration (Post Warranty)
- 3 Year
- Detection mode 2. Types of Explosives 3. Sample analyzed 4. Laser Wavelength 5. Laser Safety 6. Glove Compatibility 7. Library 8. Spectral Range & Resolution 9. Display & Size
- 1. Narcotics 2. NA 3. Solid, liquid, powder 4. 1064 nm 5. Class 3B or equivalent or better 6. Yes 7. Library should be comprised of all NDPS, NPS, precursors, controlled substances, pharmaceuticals, and chemicals as per NDPS Act. Customisable and upgradable. 8. 200 cm?¹ – 2000 cm?¹ or better & <12 cm?¹ or better 9. 4 inch
- Each Sample collector uniquely bar coded 11. Number of Sample Collectors 12. IP Protection 13. Availability of Radiation Safe Certificate 14. Type of Display
- 10. Yes – Mandatory 11. 200 Vials 12. IP 67 and Above 13. Yes – Mandatory 14. Color TFT/Touchscreen LCD
- Weight 16. Battery Life 17. Min Temp Operating 18. Support 19. Training
- 15. <2000g 16. Minimum 04 Hours of continuous use or better 17. -5 degree Celsius 18. 24*7 support & resources in hybrid mode for troubleshooting & guidance 19. Mandatory Training of NCB Staff at consignee location
- Sensitivity to Narcotics/Explosives 21. Maximum Operating Temperature 22. Memory 23. Analysis/Detection time 24. Geo Tagging
- 20. NA 21. 50 Degree Celsius 22. As per the Compliance of the Device 23. Less Than 300 Seconds 24. Geo tagging enabled