Fully Automated Urine Analyzer
500052,Shivarampally, Rajendra nagar, Hyderabad
- Delivery
- 15 days
Specifications & requirements · 69
- Specification Name
- बड के िलए आवPयक अनुमत मूWय /Bid Requirement (Allowed Values)
- Product Name
- Fully Automated Urine Analyzer
- Type of configuration
- Benchtop
- Analysis provided
- Combination of Urine Chemistry and Urine Sedimentation
- Type of loading
- Continuous
- Working Principle of Sedimental analysis
- True Microscopy (Auto Image Evaluation Module)
- Working principle of Chemical Analysis
- Reflectance Photometry
- Type of sample
- Urine
- Minimum Sample Volume in ml
- ? 5
- Chemical Testing Parameters
- Glucose, Protein, pH, Specific gravity, Urobilinogen, Bilirubin, Ketones, Nitrites, Blood &Leucocytes, Microalbumin & Creatinine with ACR and PCR ratio (If strips protected against ascorbic acid)
- Sedimental testing parameters
- RBC, WBC, CAST, Crystals, Epitheliul cells, Sperms, Bacteria, Squamous Epitheliul cells. Non Squamous Epithelial cells ,WBC Clumps, Yeast, Mucus
- Capability to analyze other body fluids
- No
- Capability to Analyze Osmolality
- No
- Physical characteristics measured by the system
- Clarity, Specific gravity, Colour, Turbidity
- Flagging of Atypical Cells/WBC clumps for Sediment
- Yes
- Flagging of Atypical Cells/WBC clumps for Combination
- Yes
- Thoughput (Number of Sample) for Chemistry
- 101 to 150
- Specification Name
- बड के िलए आवPयक अनुमत मूWय /Bid Requirement (Allowed Values)
- Thoughput (Number of Sample) For Sedimentation
- 60 to 100
- Minimum Consumable Loading Chemistry
- 100 to 200
- Reagent Type for Chemistry
- Strip
- Reagent Type for Sediment
- Solid consumables
- Dry Strip Detection
- Yes
- Attached Waste Bin Container
- Yes
- Availability of Quality control program in system
- Yes
- System should have provision to avoid sedimentation cross contamination by performing sample to sample cleaning
- Yes
- Modular/upgradable feature
- Yes
- RBC Morphology information
- Isomorphic
- UTI Flagging
- Yes
- Bacteria Classification
- Yes
- Calibration
- Calibration Strips and Automatic
- Type of user Interface
- Barcode Reader Facility
- Type of Barcode Reader
- External
- Type of Patient Data Entry
- Alpha-Numerical
- Data memory (Number of Patients and QC data)
- > 10000
- HIS/LIS Interface
- RS232
- Number of USB Port provided
- 2
- Result and worklist transmission through LIS
- Yes
- Printer facility
- Yes
- Printer unit
- NA
- Printer type
- NA
- Type of data management
- PC based
- PC monitor type
- LCD/LED
- PC monitor size in inches
- 15 or more
- Inbuilt Display
- LCD/LED/TFT
- Touchscreen in Inbuilt Display
- No
- Inbuilt monitor size in inches
- NA for PC Monitor
- Specification Name
- बड के िलए आवPयक अनुमत मूWय /Bid Requirement (Allowed Values)
- The processor and RAM of the PC board system should be Compatible
- Yes
- Sediment analysis
- 15 or more Images per Sample
- Number of USB port
- 2
- System should be provided with compatible software and software updates to be provided during the warranty period
- Yes
- Analyser should have facility for operator to zoom the images for closer viewing
- Yes
- OEM is manufacturing Quality controls
- Yes
- Type of power supply in VAC,Hz
- 220-240 VAC,50-60 Hz single phase
- UPS provided
- No
- UPS Back up Time (in minutes)
- NA
- Number of consumable provided with the machine
- 100 Tests
- Compliance to Medical Device Rules (MDR) 2017 as amended till date
- Yes
- Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date
- Yes
- Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date
- Yes
- Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement
- Yes
- Electrical Safety
- IEC 60601 or Equivalent BIS
- Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue)
- 1, 2, 3, 4, 5 Or higher (year)
- Test Modes
- • Dry chemistry mode • Formed element mode • Integrated dry chemistry + formed element analysis mode
- Throughput Test Modes
- • Dry chemistry mode throughput shall be minimum 120 tests/hour. • Formed element mode throughput shall be minimum 100 tests/hour. • Integrated analysis throughput shall be minimum 100 tests/hour.
- Test Parameters
- • Physical examination including color and turbidity • Dry chemistry testing for minimum 11/14 parameters • Formed element analysis for total 37 urine formed elements
- Dry Chemistry Parameters
- • BLD • BIL • KET • GLU • PRO • NIT • LEU • pH • SG • UBG • ASC • CRE • Ca • MCA • ACR • UCa/Cr
- Imaging and AI Recognition System
- AI Technology • The analyzer shall utilize AI DeepCell engine technology. • The system shall support convolutional neural network and mixed intelligent perception technology. • Recognition accuracy for urine formed elements shall be greater than 90%.
जीएसट पर इनपुट कर Eे<डट /ITC on GST · जीएसट उपकर कर Eे<डट /ITC on GST Cess · लागू आरसीएम/R CM Applicabl e · Uरवस % 9भार के अनुसार जीएसट/GST as per RCM · Uरवस % 9भार के अनुसार जीएसट उपकार 1 /GST Cess 1 as per RCM · GST Cess 2 as per RCM · वैक5Wपक Uरवस% 9भार /Optional RCM
NA · NA · Yes · 18% · 9% · 9 (INR) - Per Unit · Yes