Vault (Strong Room) Door As Per IS 11188
313324,RBO Rajsamand, Hotel Govindam Inn, Near TVS Chauraha, Kankroli
- Delivery
- 15 days
Specifications & requirements · 36
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूVय /Bid Requirement (Allowed Values)
- Type of Vault (Strong Room) Door
- Vault Main Doors, Vault Emergency Doors
- Classification of Vault (Strong Room) Door
- B Class - TRTL 30, FR 30
- Opening of Door
- Right Hand Side
- Height of Door (Maximum) in mm
- 1200, 2300
- Specification Name
- बड के िलए आवPयक अनुमत मूVय /Bid Requirement (Allowed Values)
- Height of Door (Minimum) in mm
- 900, 2100
- Width of Door (Maximum) in mm
- 1250, 1400
- Width of Door (Minimum) in mm
- 1100, 1250
- Inside Height or clear opening of Door, when the shutter swings 180º in mm
- 600, 1950
- Inside Width or Clear Opening of Door, when the shutter swings 180º in mm
- 750, 900
- Minimum Thickness of door frame in mm if the door frame is made by single plate which is multi bended to form the door frame
- 10, NA
- Minimum Thickness of door frame in mm if the door frame is made by fabricating angle or any channel
- 10, NA
- Thickness of Angles for Grill Gate
- Above 5 (millimeter)
- Diameter of Grill Gate Road
- Above 19 (millimeter)
- Minimum Pitch of Grill Gate Road
- Up to 100 (inch)
- Thickness of Door Slabs over Rebates in mm
- ?29
- Thickness of Door Slabs over Lock in mm
- ?50
- Thickness of drill and oxyacetylene torch resisting layer (excluding mild steel plates)
- ?20
- Door Wall Thickness in mm
- 305~380
- Actual Wall Thickness in mm
- Any applicable numeric value (millimeter)
- Number of Shooting Bolts on Hinge Side
- 3, 6
- Number of Shooting Bolts on Opposite Hinge Side
- 3, 6
- Number of Shooting Bolts on Top
- NA
- Number of Shooting Bolts on Bottom Side
- NA
- Specification Name
- बड के िलए आवPयक अनुमत मूVय /Bid Requirement (Allowed Values)
- Cross section Area of Single Shooting Bolt
- Any applicable numeric value (square meter)
- Depth of Engagement of Shooting Bolt in mm
- ?15
- Compression Mechanism
- A continuous resilient packing is incorporated in the frame for compression mechanism for clenching the door tight against this packing in doors, this helps liquids or gases to pass through, NA
- Time Lock (Optional)
- The locking mechanism, shooting bolt mechanism and door design and construction is done in such a way that there are provisions for fixing time lock in the main Vault (Strong Room) door at the latter date for Class A, Class AA, Class AAA, NA for C Class, B Class and All Emergency Vault(Strong Room) Door, NA
- Doors are Tested as approved by BIS
- Class B Burglary resistance as per IS 11188 Part 2, Fire Endurance 11188 Part 3, Fire Hose Stream Reheat 11188 Part 4
- Warranty Period
- 1, 2, 3 (year)
- of Product Cost Payable on Product Delivery
- 70%
- Min Cost Allocation for ICT as a % of product cost
- 30%
- Number of days allowed for ICT after site readiness communication to seller
- 10 Days