22 facts from the tender

Ministry of Railways published this works tender on eProcure on 8 Oct 2026, for Mumbai. The estimated value is ₹16.3 Cr and the EMD is ₹32.6 L. It closes on 2 Nov 2026, 3:00 pm IST. Tender ID 92364865 · Ref SG_217_2_314_WA.

Timeline

  1. Published8 Oct 2026 · 3:50 pm
  2. Closes2 Nov 2026 · 3:00 pm

Bidding

Bid type
Open/Advertised
Contract type
Works - General · Expenditure
Tender type
Open
Tendering section
SIG/SOUTH
Bidding system
Two Packet System
Bidding style
Single Rate for Each Schedule
Validity of offer
90 days
Completion period
12 Months
Tender document cost
None
JV / consortium
JV allowed (up to 3 members), no consortium
Ranking order
Lowest to Highest
Expenditure type
Capital (Works)
Pre-bid meeting
None

Buyer

Inviting authority
MUMBAI CENTRAL DIVISION-S AND T/WESTERN RLY
Organisation type
Central Govt. Ministry/Department
Product category
Railway related Products
Location
Mumbai
Portal
eProcure
Inviting officer
Sr.DSTE/BCTMUMBAI CENTRAL DIVISION-S AND T/WESTERN RLY

Important dates

Published
8 Oct 2026, 3:50 pm IST
Bidding starts
19 Oct 2026
Closes
2 Nov 2026, 3:00 pm IST

Declarations by the buyer

  • Complies with the Public Procurement (Make in India) Order 2017
  • The tender inviting authority confirms this tender does not violate the GFR rules on procurement through GeM
  • Bidders from a country sharing a land border with India must be registered with the competent authority

Schedule of work

103 items
ItemQuantityRailways’ estimated rateAmount
Schedule A1 · Supply & Installation OF MSDAC
1Supply of Multi Section Digital Axle Counter (MSDAC) for mentioned detection Point by the purchased & track Section as per SIP, complete with all accessories, cable required with each track device & card viz. Axle detectors, Track Side Electronics/DAC field units, Central Evaluator (Central Evaluator unit should be housed in a pre-fabricated rack to be supplied along with the system), reset unit, Relay unit, Event Logger & Diagnostic terminals, etc. Required for different Detection Points & Track Sections as per RDSO Specifications No. RDSO/SPN/176/2013, Ver.3 or latest and OEM/manufacturer's specification and as per Annexures. (Quantity 01 No. = 01 DP) . Note:- As per WR's Policy No 03/2024 Para No. 3.4.2 .e .iv "VDU/Reset box can be used for resetting. At Stations having more than 10 Track sections, the Railway propose to use a separate VDU-based resetting system. Such a VDU-based system if using a PC, it must be industrial grade".Numbers=Per DP319 Numbers₹2,70,290.46₹8,62,22,656.74
2Installation of track device (double rail contact) including digging of trench, track crossing, laying of anti-rodent, anti-oxidant & non-flame propagating type Double Walled Corrugated (DWC) pipe as per IS- 14930 part- I or II or latest and all other accessories as per site requirement to be for laying of transmitter and receiver cable. The item also includes installation of EJB / Track side Electronics including foundation & earthing as per OEM's guidelines and Technical requirement & specification with their own material. NOTE: Installation / programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/RDSO preferably by Authorized representative of OEM.Numbers=Per DP319 Numbers₹9,598.84₹30,62,029.96
3Installation of Central Evaluator of axle Counter, wiring from CT rack to Central Evaluator, installation and wiring of the reset box, LV box (if required) and associated power supply wiring. This includes supply of shielded cable of required conductor size for wiring between CT rack to evaluator rack, all other wires, power supply cable and wiring materials. The power supply cable from power room to Central Evaluator should not be less than 10 sq.mm PVC wire. Earthing as per OEM's guidelines & specification with their own material. This also includes painting and writing work on evaluator as per site requirement. NOTE: Installation /programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/ RDSO preferably by Authorised representative of OEM65 Numbers₹8,777.36₹5,70,528.40
4Supply of Tools Kit for Digital Axle Counter (Multi section/Single section). (MSDAC comply to the RDSO spec.No. RDSO/SPN/176/2013/Ver.3 or latest and manufacturer's specification and SSDAC comply to the RDSO/SPN/177/2012,Ver.3 or latest respectively). The tool kit shall be minimum equipped with the following equipments: (i) All mechanical tools shall be of reputed make like Taparia/Bosch etc. (ii) Digital multimeter true RMS type of make Fluke 189 or similar reputed make with probe set - 1 No. (iii) Adjustable torque wrenches 25-135 N/mtr with 13 mm and 19 mm inserts- 1 set (iv) Set of spanners screw drivers and soldering iron - 1 set (v) Dummy wheel - 1 No. (vi) Marking Jig - 1 No. (vii) Adapter card - 1 No. (viii) Extended wired socket to interface with diag No. stic plug - 1 No. (viii) Selector switch on panel base - 1 No. (ix) DAC EC card puller etc6 Numbers₹1,06,986.90₹6,41,921.40
5Installation, wiring & testing / commissioning of Axle Counter's Reset Box of all types in Cabin/Panel room and wiring the same to integrate with the Axle counter as per the instructions of Railway Engineer at site. This includes laying & termination of cable if any form Panel Room/Axle Counter room /Relay room to Reset Box in DWC pipe / existing ladder.(When reset box is shifted from existing building to new building ).6 Station₹5,855.91₹35,135.46
Schedule A2 · IPS Supply and installation
1SMPS based Integrated Power Supply System for Electronic Interlocking as per RDSO/SPN/165/2023 version -4 amend. 1 or latest and Drg No. CSTE/6295 sheet 2 of 4. This includes transportation, installation and Commissioning of Integrated Power Supply System.5 Numbers₹14,42,756.70₹72,13,783.50
2Installation, Wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 10mm thick Phenolic hylam sheets or any standard make with connections suitable for 32 A. Wiring to be done considering site requirement, depending upon the load with suitable wires, lugs & glands as per instructions of Engineer-in-charge. The work includes installation of Thermo flasher relay, ELD's, fixing & wiring of change over switch (program switch) for selection of DG set supply (DG1 & DG2) and wiring of change over switch (program switch) for selection of mains or DG supply. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room etc.For station5 Numbers₹1,09,014.46₹5,45,072.30
Schedule A3 · Supply and installation of UFSBI
1Supply, Installation, Testing and Commissioning of Universal Fail Safe Block Interface for Double Line IBS operation as per Spec. IRS S-104/2012 Ver- 0 suitable to work on OFCchannel and Quad Cable. This also includes supply and installation of modem and media changeover. The installation activity will be only considered complete only after IBS has been made functional the satisfaction of Engineer Incharge. This includes supply of relays and related accessories complete and One pair equals to 2 nos. Note-Installation testing and commissioning shall be done by RDSO approved equipment manufacturer and pre commissioning checklist should be signed jointly by representative of RDSO approved equipment manufacturer & railways.10 Set₹8,29,776₹82,97,760
2Transportation, Installation, configuration, Wiring. Testing and Commissioning of UFSBI as per RDSO Spec No. IRS:S- 104/2012 Ver.0 and Non-Vital Mux at the respective locations3 Job₹3,00,000₹9,00,000
Schedule A4 · Signalling Supply
1Fuse auto changeover system for used in Railway Signaling System as per RDSO/SPN/209/2012 version 2.0 with latest amendments. One Automatic changeover Unit comprise 32 nos. of external Non Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Per Unit=Per Module17 Per Unit₹29,743.63₹5,05,641.71
2"Surge Protection Device (Type I + II) for three phase with feature of Progressive indication of the arrestor, I imp (10/350 Micro Sec) (L-N) = 25 KA, I imp (10/350 Micro Sec) (N-PE) = 100 KA In (8/20 Micro Sec) (L-N) = 60 KA, In (8/20Micro Sec) (L-PE) = 100 KA, Voltage Protection Level (L-N) with I (25 KA) < 1.25 KV, & (N-PE) <1.50 KV Make: CONTRADE /ZOTUP OR Similar With KEMA/VDE approved lab testing Report"18 Numbers₹21,240₹3,82,320
3Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated.6 Numbers₹24,008.12₹1,44,048.72
4Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028 .[Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated.14 Numbers₹26,249.42₹3,67,491.88
5Miniature, Plug-in Type, M to C, DC Neutral Line, Non ACImmunised Relay, Style QN1, 24 V DC, 8F-8B/12F-4B Contact complete with plug board, retaining clip and connectors, Code ABCDF/ABCDE Spec: BRS:930 ;IRS S 34 ; IRS S 23,STR: STR SIQ 0420 ver 1.2287 Numbers₹4,284.48₹12,29,645.76
6"Miniature, Plug-in Type, M to C, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F-4B Contact complete with plug board, retaining clip and connectors, Code ABDGH/ABDFHSpec:BRS:931A ; IRS S 34 ;IRS S 23 ;IRS S 60-78 STR:STR SIQ 0420 ver 1.2"287 Numbers₹5,576.04₹16,00,323.48
7"Miniature, Plug-in type, M to C, DC Neutral Line Relay, 24V DC1000 Ohm , ACI Style- QNA1K, 6F-6B/4F-4B Contact complete with plug board, retaining clip and connectors, Code CDEKY/CDEKYSpec: BRS:931A & STs/E/Relays/UEA/PI dtd 30.05.97 Annex II & IRS:S-23@ 44"38@ 60 STR: STR SIQ 0420 ver 1.2"74 Numbers₹5,859.41₹4,33,596.34
8Soldering Wire resin core 60/40, 18 SWG (PHILCO / KHOSLA MAKE or similar)6 Kg₹1,333.85₹8,003.10
9Tag block 96/100 way with polycarbonate covers as per requirement (IRS S-77/2006 rev 1or latest).9 Numbers₹1,381.25₹12,431.25
10Tag block 200 way with polycarbonate covers as per requirement (IRS S-77/2006 rev 1 or latest).42 Numbers₹2,310.84₹97,055.28
11Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3).60 Kilometre₹5,496.94₹3,29,816.40
12PVC insulated Railway Signaling multi-core Indoor Cable 1mm x 60mm x 0.6 mm diameter conforming to IRS:76/89(Amd3) or latest.6 Kilometre₹1,74,705.11₹10,48,230.66
13PVC insulated Railway Signaling multi-core Indoor Cable 1 mm x 40 mm x 0.6 mm diameter conforming to IRS:76/89(Amd3) or latest.6 Kilometre₹92,180.73₹5,53,084.38
14PVC insulated Railway Signaling multi-core Indoor Cable 1mm x 24 mm x 1 mm dia conforming to IRS:76/89(Amd3) or latest.6 Kilometre₹1,83,153.70₹10,98,922.20
15"Indoor PVC jumper wire (tinned) of all colours as per IRS S:76/89 with latest amendment. 1 x 1 mm Note:- Wire Colours and quantities shall be specified by Engineer-in-charge."6 Kilometre₹6,303.27₹37,819.62
16Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 + 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89.6 Kilometre₹1,36,063.55₹8,16,381.30
17Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89.3 Kilometre₹1,32,505.12₹3,97,515.36
18Supply of 35 Sq.mm multistrand single core PVC insulated copper cable as per IS: 694.3,000 Metre₹345.80₹10,37,400
19Distribution Cum Auto-changeover Box between two DC supplies of Reliance Make, GAEC or similar with capacity 70A consisting of suitable Contractors of Siemens /L&T make Or Programmable Solid state type Distribution Cum Auto-changeover Box. LED Lamps, Push Button, MCB, Wago Terminals etc. Terminals & Wires should be for appropriate ratings & accessories like Lugs for wire terminations to be provided.(To be got approved from Engineer in Charge before supply).4 Numbers₹49,929.20₹1,99,716.80
20Distribution Cum Auto-changeover Box between two DC supplies of Reliance Make ,GAEC or similar, with capacity 32A consisting of suitable Contractors of Siemens /L&T make Or Programmable Solid statetype Distribution Cum Auto-changeover Box. LED Lamps, Push Button, MCB, Wago Terminals etc. Terminals & Wires should be for appropriate ratings & accessories like Lugs for wire terminations to be provided.(To be got approved from Engineer in Charge before supply).1 Numbers₹49,564.03₹49,564.03
21Distribution Cum Auto-changeover Box between two AC supplies of Reliance Make, GAEC or similar with capacity 38A consisting of suitable Contractors of Siemens /L&T make Or Programmable Solid state type Distribution Cum Auto-changeover Box. LED Lamps, Push Button, MCB, Wago Terminals etc. Terminals & Wires should be for appropriate ratings & accessories like Lugs for wire terminations to be provided.(To be got approved from Engineer in Charge before supply).2 Numbers₹40,776.29₹81,552.58
22SS Location box made of Spl Grade SS 304 of size as per drg. No.DRM/SG/948 dt. 31.01.2024 rev 2 (Single app. Case). Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply.16 Numbers₹59,855.98₹9,57,695.68
23SS Location box made of Spl Grade SS 304 of size as per drg. No.DRM/SG/945 dt. 31.01.2024 rev 2 (Half app. Case). Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply.38 Numbers₹51,998.06₹19,75,926.28
24Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197 ver 1.054 Numbers₹10,403.08₹5,61,766.32
25Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer-in-Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3)8,820 Numbers₹58.53₹5,16,234.60
26Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Supply of End plate for above item (I) 2.5mm/0.091 in thick as per site requirement.2,205 Numbers₹11.07₹24,409.35
27Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Supply of End Stopper for above item (I) 10mm/0.0394 in width as per site requirement.2,205 Numbers₹10.86₹23,946.30
28Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments .Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement.144 Metre₹113.88₹16,398.72
29Anti rusting paste for disconnect terminal block (20 ml) Alu plus syringe 249 series or similar.441 Numbers₹150.09₹66,189.69
30Medium Class G.I. Pipes to IS : 1239 (Pt.I)-2004 or latest ; 100mm dia. ( int. dia) 3.65 mm+/-10% thick with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.110 Running Metre₹1,170.28₹1,28,730.80
31Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.115 Numbers₹1,912.20₹2,19,903
32Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 50 mm outer dia, & 38 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.3,017 Numbers₹406.55₹12,26,561.35
33Pad locks Godrej make, Hardened Nav-Tal 7 lever, 65mm dia with common key or similar product having same feature & technical data.54 Numbers₹196.79₹10,626.66
34Program switches, snap action, base mounting type along with acrylic cover and mounting bracket, 63A, 9 poles, and 3 positions make Siemens /Thakur or Similar.12 Numbers₹10,714.45₹1,28,573.40
35"Power Distribution board consisting of following :25Sqmm Lugs - 50 nos, 16Qqmm lugs - 50 nos, D Type fuse (2-25A capacity) - 50 Nos.-D Type fuse (35-63A capacity) - 25Nos.etc along with required material ."4 Lumpsum₹16,631.76₹66,527.04
36Supply of 4 connection points single potential throughs screwless terminal block for 6-sq.mm- 35 sq.mm 4 connection point 284-621/ 624 or Superior suitable for Power cable connection.60 Numbers₹289.94₹17,396.40
37IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x854 Numbers₹5,388.67₹2,90,988.18
38ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.7,116 Numbers₹75₹5,33,700
39Supply of Pre wired 28-U floor mounting MS cabinet suited to fit 3 Nos. of UFSBI electronics.10 Each₹1,95,750₹19,57,500
40Supply of Dual Fiber Modem along with Auto changeover facility compatible with UFSBI system as per IRS:S-104/2012 Ver.0. with latest amendment.20 Each₹56,640₹11,32,800
41Supply of Miniature, Plug in Type, M to C, Twin, DC Neutral, Line relay ACI, Style QNNA1, 24 V DC, 6F-2B & 6F-2B /4F-4B & 4F-4B Contact, Code CDEHX/ACDHJ Spec:BRS:960 ; IRS S 34 ; IRS S 23 ;IRS S 60-78 STR:STR SIQ 0420 ver 1.2417 Numbers₹6,039.60₹25,18,513.20
42Supply of 24 Fiber Armoured Optical Fiber Cable as per latest RDSO specification.3,000 Metre₹60.66₹1,81,980
43Supply of Permanently Lubricated HDPE Telecom duct size 40/33 mm and accessories as per specification.3,000 Metre₹65.14₹1,95,420
44Provision of 10" Data input system with stylus pen of reputed make as decided by Engineer in charge.3 Numbers₹28,482.30₹85,446.90
Schedule B1 · Execution
1Excavation of cable trench as per cable route plan,1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.1,900 cum₹839₹15,94,100
2Digging of trench 1.2 M deep from rail flange/road level and, 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe. (Placing of DWC/RCC/GI pipe coverd separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No.CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed.135 cum₹873.93₹1,17,980.55
3Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform /Road /Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.450 cum₹512.76₹2,30,742
4As and when required by the Engineer in charge arranging /providing of labors for various safety related works such as protection of track etc. with contractor's T&P, equipment,hand signal flags, spanners,hammers, etc. as per specification special conditionsand detailed scope of work as furnished in the tender and directed by the engineer incharge180 Man-Days₹649.71₹1,16,947.80
5Removal of Rail (13 mtrs.) in the way of cable route. In case of panel (39 Mtrs. Each) will be consider as three rails for payment purpose.60 Numbers₹96.82₹5,809.20
6Removal of PRC Sleeper in the way of cable route.60 Numbers₹107.43₹6,445.80
7Placing of DWC/RCC/GI pipes along with collars in trenches at places of track and road crossings, platform cuttings etc.18,902 Running Metre₹35.95₹6,79,526.90
8Laying of S&T Cables of various cores/pairs/quads in trenches/GI pipes/RCC pipes/DWC pipes/Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be maggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.1,28,000 Running Metre₹9.37₹11,99,360
9Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.15,936 Numbers₹22.75₹3,62,544
10Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.6,100 Numbers₹23.70₹1,44,570
11Digging of cable pit (min 2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter.6 Numbers₹12,567.83₹75,406.98
12Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.Single apparatus case16 Numbers₹7,162.63₹1,14,602.08
13Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Half apparatus case38 Numbers₹5,487.86₹2,08,538.68
14Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.45 cum₹2,061.36₹92,761.20
15Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6 . Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).50 cum₹6,259₹3,12,950
16Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Single apparatus case16 Numbers₹1,076.29₹17,220.64
17Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand.Half apparatus case38 Numbers₹657.15₹24,971.70
18Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site.Single apparatus case16 Numbers₹2,445.36₹39,125.76
19Fabrication and fixing of SMC sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783- 1/2. With latest alterations & as per instructions of Rly engineer at site. Half apparatus case38 Numbers₹777.78₹29,555.64
20Preparation and fixing of location box board on 03 mm ACP sheet with size 12 x 18 size A3 for location box including pasting of printed/ painted vinyl sheet and lamination (printing/painting of location detail on vinyl sheet covered in schedule item separately).64 Numbers₹239.73₹15,342.72
21Lettering /Numbering Termination particulars, equipment names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/Nerolac /Dulux /Berger make. Full size16 Numbers₹129.26₹2,068.16
22Lettering /Numbering Termination particulars, equipment names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/Nerolac /Dulux /Berger make. Half Size38 Numbers₹88.18₹3,350.84
23Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly engineer at site.6 Numbers₹9,184.44₹55,106.64
24Installation of Relay Rack Assembly including IDF pillars if any complete with wall supports, scaffolding, ladders, runway for cables, fixing of Relay /Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on WR & the instructions of Rly engineer at site.14 Numbers₹10,419.20₹1,45,868.80
25Circuit wiring/jumpering as per circuit diagrams in the relay racks/IDF rack tag blocks. This includes preparation of Jumper sheets by wire man duly checked by firm's site supervisor & wire to wire testing as per circuit diagram. Any wrong jumper done by wireman will not be paid & correction shall be done free of cost. Jumper wires will be issued by Railways. Good quality solder resin core to be supplied by contractor for soldering of Jumper wires. Soldering of jumper wires to be done after completion of testing by Railways.4,300 Numbers₹13.19₹56,717
26Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 60/40 core cable/flexible wire on tag block/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel troughing work. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly. Engineer at site.991 Numbers₹514.97₹5,10,335.27
27Fixing & wiring of QNA1 /QNA1K relays for GPR Circuit in apparatus case as per Standard practice. Fixing and wiring material shall be supplied by the contactor.74 Numbers₹366.58₹27,126.92
28Removal of excavated/slip earth/debris/malba from the site of works to any other place outside Railway land/premises, including all excavations, handling, re-handling, loading, unloading and leading, etc. all labour and material as a complete job. Removal of Earth (all kinds of soils)/ROCKS, BOULDERS including mud/slush, slipped earth in catch water drains, side drains, over berms in cutting, water way of bridges, over coping of toe/breast/retaining walls etc. including crossing of nallah, railway tracks, making/repairing approach roads if required, all lead, lift, ascent, descents, or any other obstruction. Earth spoils to be dumped outside the cutting or railway embankments as per direction of Engineer in charge100 cum₹192.22₹19,222
29Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.110 Running Metre₹164.25₹18,067.50
30Supply and installation of Class B and C Surgeprotection Device [SPD] -Type I and II with Visual Indication and Potential free contact to remote monitoring as per Specification No.RDSO/SPN/165/2012 Ver 3.0or latest and IEC standard 61643 for Single line 230V ACapplication with handling Lightning surges of 10/350 microseconds and Switching surges of 8/20 micro seconds.One Set consists of 3 nos. of SPD [2 No. of B Class [L-N, N-E] and one no. of C Class [L-N] all enclosed in a Box with KEMA or VDE certified as per latest IEC 61643-11-2011 Standard. Class B and C Surge protection device required with Three modules only.18 Numbers₹6,987.53₹1,25,775.54
31Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggeringreport, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD inA3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards LC/IBS/ABS6 Numbers₹19,772₹1,18,632
32Design of circuits and plans to suit layout given in the signalling plan of Automatic signalling/IBS/ABS/LC GATE. All plans and wiring diagram shall be prepared on Auto cad Drawing and supplied with CD. This will include supply of Control cum Indication panel diagram, Route section plan, square sheet, wiring diagrams, Relay rack/Relay arrangements, Bus bar details, Fuse analysis, contact analysis, Relay room tag block analysis, panel tag block analysis, Power panel diagram, IPS wiring diagram, Auto change over diagram, Power equipment arrangement with program switch, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings6 Lot₹13,872.01₹83,232.06
33Installation, Testing and Commissioning of Distribution cum auto changeover system including wiring material(Excluding Cable)7 Set₹8,325.35₹58,277.45
34Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mtr and route diversion as per Drg. No 4014/00/CC4 or latest/Stone marker.190 Numbers₹412.66₹78,405.40
35Supply and Placing of Polyolefin Cable channel of Polyolefin Cable size, Width 240/340 mm, Height 155/230 internal /PC ( INCLUDING BOTTOM AND TOP COVER ) 8.00 KG ( MIN.) LENGTH PER PC/external, length 1 m produced of polyolefin with Fire protection class k-1 in accordance with DIN-53438 Part II for laying Signalling/Telecom cables, channel attachable to each other with male-female swallow tail connectors and having suitable detachable cover.9,200 Numbers₹2,178.12₹2,00,38,704
36Installation of Maintenance Free Earth Electrode for Maintenance Free Earth spec of RDSO/SPN/197 ver 1.0.54 Numbers₹1,456.79₹78,666.66
37"Laying of HDPE pipe duct in trenches/GI Pipe/RCC pipe/on wall/on PF, including jointing and levelling using couplers and sealing the section etc as per site requirement as per specification. "3,000 Metre₹12.28₹36,840
38Blowing and drawing of OFC through laid HDPE duct as per approved route plan , taking due care while transporting and sealing both ends as per specification.3,000 Metre₹16.02₹48,060
39Supply,transportation, installation, testing & commissioning of (LEVEL - 1) Digital Earth Leakage Detector 12 channel for monitoring 110V AC/110V DC/60V DC/24V AC as per the site requirement & as per RDSO Spec. No. RDSO/SPN/256/2025 with latest amendment (LEVEL - 1).3 Numbers₹84,842₹2,54,526
40Design, Manufacture and Supply of Non-Vital Mux with 120 (102 Used +18 Spare) Inputs. Required for the exchange of Non-Vital Functions pertaining to Axle Counter Resetting, between Station Master's Building, housing Reset Boxes of MSDAC and the trackside Goomty housing the MSDAC Evaluator.4 Set₹5,00,000₹20,00,000
41Design, Manufacture and Supply of Non-Vital Mux with 120 (102) Used + 18 Spare) Outputs. Required for the exchange of Non-Vital Functions pertaining to Axle Counter Resetting, between Station Master's Building, housing Reset Boxes of MSDAC and the trackside Goomty housing the MSDAC Evaluator.4 Set₹5,00,000₹20,00,000
42Supply & installation of 24 port Rack mounted LIU along with all accessories as per specification.6 Numbers₹17,023.48₹1,02,140.88
43Supply Installation ,fixing ,Wiring,Testing & commissioning of MSDAC Indication/Alarm panel system .It shall consist of 200 LEDs of 10mm size fabricated in a box of 15mm waterproof ply6 Lumpsum₹21,252.72₹1,27,516.32
44Releasing of Existing AFTC indoor frames,Panel, Power Equipments, relays and relay racks, CT racks, Batteries, Block Instruments, Ground frame/s, Location Boxes, TLJBs, Signal Posts, Signal Units, Equipment inside the location boxes, Lifting Barrier, rodding runs etc as applicable including the breaking of foundation etc. as per the instructions of Rly Engineer at site & their transportation to nominated depot. This work to be done by contactors with his own vehicle and labour.6 Lumpsum₹14,327.92₹85,967.52
45Dismantling /Releasing of existing Signaling Gears. One Signalling gear will be all parts of one signal (consisting of CLS unit, Signal post along with base) or lever frame (5 levers set), or one point (consisting of all parts of a mechanical point, point machine, ground connections etc.) or one track circuits (consisting of battery box & other parts of DC Track circuit /AFTC /DAC) or one Block instruments etc. This includes the cost of transportation of release materials to store depot or as decided by consignee in charge. This work to be done by contactors with his own vehicle and labour.330 Numbers₹1,062.82₹3,50,730.60
46"Transportation of S&T material leading up to 1 Km including Loading from Starting point, unloading & Stacking at destination.40 MT of S&T Materials per stationOverall distance to be covered by road is 71KM"240 MT₹452.58₹1,08,619.20
47"Extra for each additional 1 Km or part there of. 40 MT x 70KM= 2800"16,800 Kilometre₹4.10₹68,880
48Installation wiring testing and commissioning of Fuse change over system (FACS). This includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible.Per Unit=Per Module.16 Per Unit₹915.42₹14,646.72
49Splicing of 24F Optical Fiber Core and routing in joint closure/FDMS as per instruction of site Engineer.144 CORE₹116.15₹16,725.60
50Laying of Jelly filled cable/24F OFC in trench/open ground/under asphalted/cemented surface/through pipes/through wall/through rail track/through Tray, including laying material as per specification.3,000 Metre₹13.85₹41,550
Total₹16,28,20,943.21

Bids quote a percentage above, below or at par with these rates · The total matches the advertised value.

Documents

3 files

Documents to submit

Commercial-Compliance

  • Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.

    Document optional

Technical-Compliances

  • Tenderer should clearly state the status of firm and submit therelevant document in support of authentication, in absence offollowing/relevant documents the offer of tenderer is summarilyrejected:

    1. Self-declaration /proprietorship certificate in case ofproprietor firm along with POA if any.
    2. Partnership deed andpower of attorney in case of partnership firm.
    3. Certified copyof an extract of resolution passed by the board of directors incase of limited firm or Private limited Company The tenderer(s)shall enclose the attested copies of the constitution of theirconcern, and copy of PAN Card along with their tender
    Document required
  • (a) Sole Proprietorship Firm: (i)All documents in terms of Para 10of the Tender Form (Second Sheet)of Tender document

    Document optional
    1. HUF:
      1. A copy of notarized affidavit on Stamp Paperdeclaring that he who is submitting the tender on behalf of HUFis in the position of 'Karta' of Hindu Undivided Family (HUF) andhe has the authority, power and consent given by othermembers to act on behalf of HUF.
      2. All other documents interms of Para10 of the Tender Form (Second Sheet)of Tenderdocument.
    2. Partnership Firm: (i)All documents as mentioned in para18 ofthe Tender Form document.
    Document optional
  • d) Company registered under Companies Act2013:

    1. The copiesof MOA (Memorandum of Association) / AOA (Articles ofAssociation) of the company
    2. A copy of Certificate ofIncorporation
    3. A copy of Authorization/Power of Attorneyissued by the Company (backed by the resolution of Board ofDirectors) in favour of the individual to sign the tender on behalfof the company and create liability against the company.
    4. Allother documents in terms Para 10 of the Tender Form (SecondSheet) of Tender document.
    Document optional
  • (e) LLP (Limited Liability Partnership):

    1. A copy of LLPAgreement
    2. A copy of Certificate of Incorporation
    3. A copy ofPower of Attorney/Authorization issued by the LLP in favour ofthe individual to sign the tender on behalf of the LLP and createliability against the LLP.
    4. An undertaking by all partners of theLLP that they are not blacklisted or debarred by Railways or anyother Ministry / Department of the Govt. of India fromparticipation intenders / contracts as on the date of submissionof bids, either in their individual capacity or in any firm/ LLP or JVin which they were/ are partners/members. Concealment /wrong information in regard to above shall make the contractliable for determination under Clause 62 of the Standard GeneralConditions of Contract.
    5. All other documents in terms of Para10 of the Tender Form(Second Sheet).
    Document optional
Show all 11
  • (f) Registered Society & Registered Trust:

    1. A copy of Certificateof Registration
    2. A copy of Memorandum of Association ofSociety/Trust Deed
    3. A copy of Power of Attorney in favour ofthe individual to sign the tender documents and create liabilityagainst the Society/Trust.
    4. A copy of Rules & Regulations ofthe Society
    5. All other documents in terms of Para 10 of theTender Form (Second Sheet) of tender document
    Document optional
  • Certificate of Information regarding EMPLOYMENT/PARTNERSHIP etc. of Retired Railway Employees with the tender as per the attached proforma, Format 11 of tender document

    Document required
  • Certificate of NO RELATIVE being an employee of Western Railway as per attached Performa Format 10 of Tender document.

    Document required

Custom

  • Please submit a certificate in the prescribed format {As per Annexure II & Annexure II-A (if applicable) of Tender Documents} for verification/ confirmation of the documents submitted for compliance of eligibility / qualifying criteria. Non submission of the certificate, or submission of the certificate either not properly filled in, or in a format other than the prescribed format shall lead to summarily rejection of your offer.

    Document required
  • Partnership firm/Joint Venture (JV) /Hindu Undivided Family (HUF) /Limited Liability Partnership (LLP)etc. Please submit Annexure II A of the Tender document by each member of a Partnership firm/JV/HUF/LLP etc. as the case may be. Non-submission of the copy of the certificate by the bidder shall result in summarily rejection of is/her bid. It shall be mandatorily incumbent upon the Tenderer to identify , state and submit the supporting documents duly self attested/ digitally signed by which he/they are/is qualifying the qualifying criteria mentioned in the Tender document.

    Document required

Eligibility

Standard Financial Criteria

  • The tenderer must have minimum average annual contractual turnover of "V/N" or "V" whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Format-6, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.

    Document required

Special Financial Criteria

  • Bid Capacity For tenders having advertised value more than Rs 10 crore wherein eligibility criteria includes bid capacity also, the tenderer will be qualified only if its available bid capacity is equal to or more than the total bid value of the present tender. The available bid capacity shall be calculated as under: Available Bid Capacity = [A x N x 2] - 0.33 x N x B Where, A = Maximum value of construction works executed and payment received in any one of the previous three financial years or the current financial year (up to date of inviting tender), taking into account the completed as well as works in progress. N= Number of years prescribed for completion of work for which bids has been invited. B =Existing commitments and balance amount of ongoing work with tenderer as per prescribe performa of Railway for statement of all works in progress and also the work which are awarded to tenderer but not yet started up to the date of inviting of tender. Note:- The Tenderer(s) shall furnish the details of-

    1. Maximum value of construction works executed and payment received in any one of the previous three financial years or the current financial year (up to date of inviting tender) for calculating A, and
    2. Existing commitments and balance amount of ongoing works with tenderer as per the prescribed proforma of Railway for statement of all works in progress and also the works which are awarded to tenderer but yet not started up to the date of inviting of tender for calculating B' Incase of no works in hand, a 'NIL' statement should be furnished. The submitted details for
      1. and
      2. above should be duly verified by chartered Accountant.
    Document required

Standard Technical Criteria

  • The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:

    1. Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or
    2. Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or
    3. One similar work costing not less than the amount equal to 60% of advertised value of the tender. Similar nature of work approved by CSTE/Western Railway. Note :- Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
    Document required
  • Defination of Similar Work Any work in connection with signaling installation and which includes relay wiring and laying & termination of cables. OR Any Telecom work which includes wiring of indoor equipments (STM or PDMUX) and laying & termination of cables. OR Any signaling work involving supply, installation, testing & commissioning of AFTC/DAC systems.

Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.

  • Please submit a certificate in the prescribed format (please download the format from the link given below). Non submission of the certificate, or submission of certificate either not properly filled in, or in a format other than the prescribed format shall lead to summary rejection of your offer. ( Click here to download the Format of Self Certification)

Check each criterion against the tender notice before you bid.

Commercial conditions

EMD
₹3,256,400
Tender fee
None

Terms & conditions

2 conditions

Technical-Compliances

  • The tenderer shall clearly specify whether the tender issubmitted on his own or on behalf of a partnership concern. Ifthe tender is submitted on behalf of a partnership concern, heshould submit the certified copy of partnership deed (PD) alongwith the tender and authorization to sign the tender documentson behalf of partnership firm. If these documents are notenclosed along with the tender documents, the tender will betreated as having been submitted by individual signing thetender documents. The tenderer whether sole proprietor, alimited company or a partnership firm if they want to actthrough agent or individual partners should submit along withthe tender or at a later stage, a power of attorney(POA) dulystamped and authenticated by a Notary public or by Magistratein favour of the specific person whether he or they be partnersof the firm or any other person specifically authorizing him orthem to submit the tender, sign the agreement ,receive money,witness measurement, sign Measurement Books, compromise,settle, relinquish any claims preferred by the firm and signed Noclaim certificate and refer all or any dispute to arbitration.Tender Documents in such cases are to be signed by suchpersons as may be legally competent to sign them on behalf ofthe firm, company, association, trust or society, as the case maybe.

  • Information as per Para 16 of GCC Part (1)(Tender form secondsheet Annex-I) related to Employment/Partnership Etc. of RetiredRailway Employees and Clauses 59 (9) & 62 (1) (xv) to GCCregarding employment etc. Of retired government officers byrailway contractors

Bidder declarations (10)

Certifications

  • I/we the tenderer (s) am/are signing this document after carefully reading the contents.

  • I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.

  • I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.

  • I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.

  • I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.

  • I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.

  • I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.

  • I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.

  • I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.

  • I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)

Similar open tenders

Soonest first

Search similar in the explorerFind this tender in the explorer

Tender notice (PDF)