Neonatal Ventilators
208002,Swaroop Nagar, Kanpur
- Delivery
- 15 days
Specifications & requirements · 53
- Specification Name
- बड के िलए आवPयक अनुमत मूXय /Bid Requirement (Allowed Values)
- Patient Type
- Neonatal
- Tidal Volume Range In ml
- 2 to 300, 2 to 700
- Trigger Sensitivity Mechanism
- Pressure, Flow, Pressure and Flow
- Flow Pattern/Waveform Adjustment
- Yes, No
- Sigh Breath Function
- Yes, No
- Leak Compensation Available
- Yes, No
- Auto 100% increase O2 Button
- Yes, No
- Inspiratory Pause Available
- Yes, No
- Expiratory Hold Available
- Yes, No
- Suction Control Option Available
- Yes, No
- Nasal CPAP Option Available
- Yes, No
- Auto PEEP Manoeuvre
- Yes, No
- Control Panel Lock
- Yes, No
- Facility for double lung ventilation
- Yes, No
- Integrated Air Compressor
- Yes, No
- PSV(Pressure supported ventilation)
- Yes, No
- P-CMV(Inspiration pressure control)
- Yes, No
- PC-AC With Expiratory Minimal volume
- Yes, No
- SIMV(Synchronized intermittent Mandatory Ventilation) with PCMV
- Yes, No
- ITT - Inspiratory Time Termination
- Yes, No
- CPAP:Continuos Positive Airway pressure Ventilation CPAP With backup Ventilation
- Yes, No
- High Frequency Oscillation Ventilator(HFOV)
- Yes, No
- Capnography/Co2 Monitoring
- Yes, No
- Volume Guarantee
- Yes, No
- Specification Name
- बड के िलए आवPयक अनुमत मूXय /Bid Requirement (Allowed Values)
- APRV
- Yes, No
- Oxygen Therapy
- Yes, No
- ETCO2 Inbuilt available
- Yes, No
- Disposable Neonatal breathing circuit (dual heated wire)
- 20, 50, 80, 100, NA
- Auto Feed Humidification chamber Available
- Yes, No
- Disposable Neonatal breathing circuit with single heated wire provided for inspiratory Limb with Water trap in expiratory limb available
- 20, 50, 80, 100, NA
- Output Ports Type
- HDMI, Ethernet, RJ 45, USB
- Remote Alarm Display Port
- Yes, No
- Reporting (Vent alarms and Patient Status)
- Yes, No
- View Reports on Display
- Yes, No
- Save Data to USB
- Yes, No
- Send Data Via Network
- Yes, No
- Display Type
- LCD/LED/TFT
- Display Size in Inches
- ? 10, ? 12, ? 15 Or higher
- Can be used For Patient Transport
- Yes, No
- Nasal CPAP Kit
- 10, 15, 20
- Number of Disposable flow sensor
- 20, 50, 100, NA if Reusable
- Number of Reusable flow sensor
- 3, 6, NA if Disposable
- Trolley with ventillator with supporting arm from same manufacturer
- Yes, No
- Autoclavable exhalation valve/expiratory cassette
- 2, 3
- Test Lung Available
- Yes
- Operating time of battery in min
- 30, 60, 120
- Comprehensive Maintenance ( Minimum Percentage )
- 3 %
- Comprehensive Maintenance ( Maximum Percentage )
- 25 %
- Warranty of required product
- 5 Year
- Comprehensive Maintenance Duration (Post Warranty)
- 5 Year
- Specification
- As per ATC