Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2), LED Luminaire For Floodlight Conforming To IS 10322 (Part 5/Section 5) (V3), LED Luminaire For Road And Street Lights Conforming To…
Indian Army
Ministry of Defence › Department of Military Affairs
Delivers to
Udhampur, Jammu and Kashmir
Overview
10 facts from the tenderMinistry of Defence published this goods tender on GeM on 15 Oct 2026, for Udhampur, Jammu and Kashmir. The estimated value is ₹36.6 L and the EMD is ₹1.1 L. It closes on 26 Oct 2026, 6:00 pm IST. Bid number GEM/2026/B/8151398.
Timeline
- Published15 Oct 2026 · 6:13 pm
- Closesin 10d 15h26 Oct 2026 · 6:00 pm
- Reverse auctionIf the bid qualifies, after evaluation
Bidding
- Bid type
- Bid
- Evaluation method
- Total value wise evaluation
- Packet type
- Two Packet Bid
- Reverse auction
- Yes, H1-Highest Priced Bid Elimination
- Total quantity
- 5,532
Buyer
- Created by
- rajeevkm305-cgo@gov.in
- Location
- Udhampur · Jammu and Kashmir
- Portal
- GeM
Important dates
- Published
- 15 Oct 2026, 6:13 pm IST
- Closes
- 26 Oct 2026, 6:00 pm IST
Items & delivery
92 items · Address masked by GeM
***********Udhampur
GeM masks the full address in this document.01Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 150
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
02Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 95
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
03Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 120
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
04Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 300
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
05Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 400
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
06Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 70
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
07Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 50
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
08Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity1 setDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 240
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
09Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 185
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
10Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 25
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
11Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 35
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
12Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 2 and Part 3) Working Voltages from 3.3 kV up to and including 33 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3
- Applicable cable size for using the joint kits (in sq mm)
- 240
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
13Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity2 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 2 and Part 3) Working Voltages from 3.3 kV up to and including 33 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3
- Applicable cable size for using the joint kits (in sq mm)
- 120
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
14Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 2 and Part 3) Working Voltages from 3.3 kV up to and including 33 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3
- Applicable cable size for using the joint kits (in sq mm)
- 185
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
15Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity4 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 2 and Part 3) Working Voltages from 3.3 kV up to and including 33 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3
- Applicable cable size for using the joint kits (in sq mm)
- 95
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
16Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 2 and Part 3) Working Voltages from 3.3 kV up to and including 33 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3
- Applicable cable size for using the joint kits (in sq mm)
- 150
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
17Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 2 and Part 3) Working Voltages from 3.3 kV up to and including 33 kV
- Type of joint kit
- Non Rigid - Transition Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 50
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
18Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Transition Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 150
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
19Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 2 and Part 3) Working Voltages from 3.3 kV up to and including 33 kV
- Type of joint kit
- Non Rigid - Straight Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Copper
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3
- Applicable cable size for using the joint kits (in sq mm)
- 185
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
20Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Transition Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- PVC (Range of approval: PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 185
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
21Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Transition Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 400
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
22Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Transition Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 240
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
23Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Transition Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- PVC (Range of approval: PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 35
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
24Cable Joint Kit Suitable For Cables Up To And Including 33 KV (V2)Quantity3 setsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Conformity of the specification
- As per IS 13573 (Part 1) Working Voltages from 1.1 kV up to and including 3.3 kV
- Type of joint kit
- Non Rigid - Transition Joint - Heat Shrink
- Applicable conductors for using the joint kits
- Aluminium
- The appropriate cable insulation for using the joint kits [Ref. Cl. Table 2 of IS 13573 Part 1)]
- XLPE (Range of approval: XLPE, EPR, HEPR, PVC)
- Applicable cable core for using the joint kits (in Nos)
- 3.5
- Applicable cable size for using the joint kits (in sq mm)
- 70
- Joint kit contains (Hint: According to the type of cable, the cross sectional area of the cable and number of cores)
- Heat Shrink Stress Control Tubing, Heat Shrink Insulating Tubing, Heat Shrink Co-extruded Dual Wall Tubing, Heat Shrink Outer Jacket Tubing, G. I. Mesh Type Metallic Cannister, Tinned Copper Earthing Braid, Jubilee Clamp, Backup Ring, Mastic Tapes, Tinned Copper Binding Wire, Core Cleaning Solvent, Nylon String, Aloxite Tape, PVC (A) Tape, Silicon Grease, Tinned Copper Mesh for screen continuity, Solder, Flux, Mopping Cloth, Connector (ferrules), Instruction Sheet
25LED Luminaire For Floodlight Conforming To IS 10322 (Part 5/Section 5) (V3)Quantity6 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- System Wattage (in Watt)
- 180
- Minimum LED Luminaire System Efficacy (in lumen/watt)
- 100
- LED Colour Temperature [Hint: Warm White (2700K-3000K), Bright White (3500 K-4000 K), Cool White/Daylight (5000 K- 6500 K)]
- 5700 K
- Ingress Protection (Entire Housing)
- IP66 Or higher
- Minimum Internal Surge Protection (in kV)
- 5 Or higher
26LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3)Quantity3 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- System Wattage (in Watt)
- 90
- LED Luminaire System Efficacy (in lumen/watt)
- 120, 140 Or higher
- LED Colour Temperature [Hint: Warm White (2700K-3000K), Bright White (3500 K-4000 K), Cool White/Daylight (5000 K- 6500 K)]
- 5700 K
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Ingress Protection (Entire
- IP66 Or higher
- Minimum Internal Surge Protection (in kV)
- 5 Or higher
27LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3)Quantity4 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- System Wattage (in Watt)
- 60
- LED Luminaire System Efficacy (in lumen/watt)
- 100, 120, 140 Or higher
- LED Colour Temperature [Hint: Warm White (2700K-3000K), Bright White (3500 K-4000 K), Cool White/Daylight (5000 K- 6500 K)]
- 6500 K
- Ingress Protection (Entire Housing)
- IP66 Or higher
28LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3)Quantity3 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- System Wattage (in Watt)
- 70
- LED Luminaire System Efficacy (in lumen/watt)
- 100, 120, 140 Or higher
- LED Colour Temperature [Hint: Warm White (2700K-3000K), Bright White (3500 K-4000 K), Cool White/Daylight (5000 K- 6500 K)]
- 6500 K
- Ingress Protection (Entire Housing)
- IP66 Or higher
- Minimum Internal Surge Protection (in kV)
- 4, 5 Or higher
- Bis Required
- Yes
29LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3)Quantity2 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- System Wattage (in Watt)
- 45
- LED Luminaire System Efficacy (in lumen/watt)
- 100, 120, 140 Or higher
- LED Colour Temperature [Hint: Warm White (2700K-3000K), Bright White (3500 K-4000 K), Cool White/Daylight (5000 K- 6500 K)]
- 6500 K
- Ingress Protection (Entire Housing)
- IP66 Or higher
30LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3)Quantity1 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- System Wattage (in Watt)
- 72
- LED Luminaire System Efficacy (in lumen/watt)
- 140 Or higher
- LED Colour Temperature [Hint: Warm White (2700K-3000K), Bright White (3500 K-4000 K), Cool White/Daylight (5000 K- 6500 K)]
- 5700 K
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Minimum Internal Surge Protection (in kV)
- 5 Or higher
31LED Luminaire (Recessed Luminaire) (Ceiling Light) Conforming To IS 10322 (Part 5/Section 2) (V4)Quantity18 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- System Wattage (in Watt)
- 36
- LED Luminaire System Efficacy (in lumen/watt)
- 100 Or higher
- Shape of the Fixture
- Square
- Size of the Fixture
- 600 mm x 600 mm
- LED Colour Temperature [Hint: Warm White (2700K-3000K), Bright White (3500 K-4000 K), Cool White/Daylight (5000 K- 6500 K)]
- 6500 K
- Type of Mounting
- Recessed
32LED Garden Light (V2)Quantity3 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Type of Garden Light
- Bollard type with Pole and LED lantern/luminaire, Architectural design with pole and LED lantern/luminaire, LED post top lantern/luminaire with pole
- Material of Garden Lighting pole including lighting system (lantern/luminaire) (Note: Wherever GI, MS, CI materials used, materials shall be ISI Marked)
- Aluminium casting, Galvanised Iron, Mild steel, Cast iron, LED post top with out pole. Hence not applicable
- Pole height inlcluding lantern/luminaire (in m)
- 0.5, 1, 1.5, 3, 4, 5, 6, 7, 8, without pole
- No.of lantern/luminaire with each pole (in m)
- 1, 2, 3, 4, 5, LED post top with out pole. Hence not applicable
- Type of light source - BEE star rating of LED Bulb
- SMD LED Chip
- LED Rating in each lantern/luminaire/lighting system (in Watts)
- 20.0
- LED Lamp/System efficacy in each lantern/luminaire (in lumen/watt)
- ? 105 and < 120
- In case of LED bulb - Cap designation of each lamp and holder in each lantern/luminaire
- Not applicable (for SMP LED Chip)
- Automatic Lower/Higher Cut off voltage
- Yes. Lower cut off 120 V, Higher cut off 300 V
- Protection against surges and transients - External
- > / = 10 KV, No Or higher
- Minimum Operating Temperature (in deg. C)
- -10
- Maximum Operating Temperature (in deg. C)
- 50
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Impact resistance on diffuser material (in IK)
- 0
- Protection of the entire housing (in IP) Protection of the entire housing as per IS:10322 (Part 1):1982 latest
- 65
- Length of ISI marked three core connecting wire (Provided along with each lantern/luminiare) - (in m)
- 0.5
- Warranty for free replacement of lighting systems including lightsource (in years)
- 2
- Agreed to provide Advance Sample(s) for buyer's approval before commencement of supply. ( hint: Applicable in case of orders placed against bid and not applicable in case of Direct Buying )
- No
33LED Garden Light (V2)Quantity2 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Type of Garden Light
- Bollard type with Pole and LED lantern/luminaire, Architectural design with pole and LED lantern/luminaire, LED post top lantern/luminaire with pole
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Garden Lighting pole including lighting system (lantern/luminaire) (Note: Wherever GI, MS, CI materials used, materials shall be ISI Marked)
- Aluminium casting, Galvanised Iron, Mild steel, Cast iron, LED post top with out pole. Hence not applicable
- Pole height inlcluding lantern/luminaire (in m)
- 0.5, 1, 1.5, 3, 4, 5, 6, 7, 8, without pole
- No.of lantern/luminaire with each pole (in m)
- 1, 2, 3, 4, 5, LED post top with out pole. Hence not applicable
- Type of light source - BEE star rating of LED Bulb
- SMD LED Chip
- LED Rating in each lantern/luminaire/lighting system (in Watts)
- 15.0
- LED Lamp/System efficacy in each lantern/luminaire (in lumen/watt)
- ? 105 and < 120
- In case of LED bulb - Cap designation of each lamp and holder in each lantern/luminaire
- Not applicable (for SMP LED Chip)
- Automatic Lower/Higher Cut off voltage
- Yes. Lower cut off 120 V, Higher cut off 300 V
- Protection against surges and transients - External
- > / = 10 KV, No Or higher
- Minimum Operating Temperature (in deg. C)
- -10
- Maximum Operating Temperature (in deg. C)
- 50
- Impact resistance on diffuser material (in IK)
- 0
- Protection of the entire housing (in IP) Protection of the entire housing as per IS:10322 (Part 1):1982 latest
- 65
- Length of ISI marked three core connecting wire (Provided along with each lantern/luminiare) - (in m)
- 0.5
- Warranty for free replacement of lighting systems including lightsource (in years)
- 1
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Agreed to provide Advance Sample(s) for buyer's approval before commencement of supply. ( hint: Applicable in case of orders placed against bid and not applicable in case of Direct Buying )
- No
34LED Bulkhead LightQuantity12 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material
- Plastic
- Protection
- IP55, IP65, IP66
- Driver included
- Yes
- Power
- 10.0 (Watt)
- Input Voltage
- 240.0 (Volt)
- Housing Material
- Polycarbonate
- Mounting Device
- Wall-mounting bracket
- Life Time
- 30000.0 (hour)
- Protection class IEC
- NA
- Correlated Color Temperature
- 6500.0 (Kelvin)
- Luminous flux (system flux)
- 1200.0 (lumen)
- Depth
- 75.0 (millimeter)
- Length
- 175.0 (millimeter)
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Width
- 95.0 (millimeter)
- Warranty
- 2 Or higher (year)
35LED Batten Light (LED Tube Light) (V2)Quantity30 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Wattage (in Watts)
- 20.0
- Length of LED Batten Light
- 4.0 (foot)
- Rated Luminous Efficacy (in lumen/watt)
- 110 Or higher
- LED Colour Temperature [Hint: Warm White (2700K-3000K), Bright White (3500 K-4000 K), Cool White/Daylight (5000 K- 6500 K)]
- 6500 K
36LED Batten Light (LED Tube Light) (V2)Quantity18 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Wattage (in Watts)
- 10.0
- Length of LED Batten Light
- 2.0 (foot)
37Moulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2)Quantity4 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current (in Ampere)
- 400A
- Number of Poles
- 4 Pole
- Rated Breaking Current (in KA)
- 35 KA
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Short Circuit Capacity (in KA)
- MCCB with RSCB capacity of 10/16/25/35/50/65 KA tripping range
- Rated Voltage
- 240/415 Volt 50 Hz AC
38Moulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2)Quantity2 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current (in Ampere)
- 250A
- Number of Poles
- 4 Pole
- Rated Breaking Current (in KA)
- 35 KA
- Rated Short Circuit Capacity (in KA)
- MCCB with RSCB capacity of 10/16/25/35/50/65 KA tripping range
- Rated Voltage
- 240/415 Volt 50 Hz AC
39Moulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2)Quantity2 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current (in Ampere)
- 630A
- Number of Poles
- 4 Pole
- Rated Breaking Current (in KA)
- 35 KA
- Rated Short Circuit Capacity (in KA)
- MCCB with RSCB capacity of 10/16/25/35/50/65 KA tripping range
- Rated Voltage
- 240/415 Volt 50 Hz AC
40Moulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2)Quantity2 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current (in Ampere)
- 320A
- Number of Poles
- 4 Pole
- Rated Breaking Current (in KA)
- 35 KA
- Rated Short Circuit Capacity (in KA)
- MCCB with RSCB capacity of 10/16/25/35/50/65 KA tripping range
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Voltage
- 240/415 Volt 50 Hz AC
41Moulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2)Quantity4 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current (in Ampere)
- 250A
- Number of Poles
- 4 Pole
- Rated Breaking Current (in KA)
- 25 KA
- Rated Short Circuit Capacity (in KA)
- MCCB with RSCB capacity of 10/16/25/35/50/65 KA tripping range
- Rated Voltage
- 240/415 Volt 50 Hz AC
42)Quantity5Delivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current (in Ampere)
- 100A
- Number of Poles
- 4 Pole
- Rated Breaking Current (in KA)
- 25 KA
- Rated Short Circuit Capacity (in KA)
- MCCB with RSCB capacity of 10/16/25/35/50/65 KA tripping range
- Rated Voltage
- 240/415 Volt 50 Hz AC
43Moulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2)Quantity3 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current (in Ampere)
- 200A
- Number of Poles
- 4 Pole
- Rated Breaking Current (in KA)
- 25 KA
- Rated Short Circuit Capacity (in KA)
- MCCB with RSCB capacity of 10/16/25/35/50/65 KA tripping range
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Voltage
- 240/415 Volt 50 Hz AC
44Moulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2)Quantity4 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current (in Ampere)
- 63A
- Number of Poles
- 4 Pole
- Rated Breaking Current (in KA)
- 25 KA
- Rated Short Circuit Capacity (in KA)
- MCCB with RSCB capacity of 10/16/25/35/50/65 KA tripping range
- Rated Voltage
- 240/415 Volt 50 Hz AC
45)Quantity4Delivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current (in Ampere)
- 63A
- Number of Poles
- 3 Pole
- Rated Breaking Current (in KA)
- 25 KA
46Miniature Circuit Breakers (MCB) For AC Operation Marked To IS/IEC 60898 (Part 1)Quantity49 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Number of Pole (Hint: "P" - Pole; "PP" - Protected Pole)
- 2 P with 1 PP
- Rated Current (in Ampere)
- 63
- Rated Voltage (in Volts)
- 240 / 415 V, AC
- Instantaneous Tripping Current Type
- C
- Rated Short Circuit Capacity (in Ampere)
- 10000
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Provision of Steel Sheet Enclosure for MCB
- Without enclosure
47Miniature Circuit Breakers (MCB) For AC Operation Marked To IS/IEC 60898 (Part 1)Quantity50 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Number of Pole (Hint: "P" - Pole; "PP" - Protected Pole)
- 2 P with 1 PP
- Rated Current (in Ampere)
- 40
- Rated Voltage (in Volts)
- 240 / 415 V, AC
- Instantaneous Tripping Current Type
- C
- Rated Short Circuit Capacity (in Ampere)
- 10000
- Provision of Steel Sheet Enclosure for MCB
- Without enclosure
48Miniature Circuit Breakers (MCB) For AC Operation Marked To IS/IEC 60898 (Part 1)Quantity52 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Number of Pole (Hint: "P" - Pole; "PP" - Protected Pole)
- 2 P with 1 PP
- Rated Current (in Ampere)
- 25
- Instantaneous Tripping Current Type
- C
- Rated Short Circuit Capacity (in Ampere)
- 10000
- Provision of Steel Sheet Enclosure for MCB
- Without enclosure
49Miniature Circuit Breakers (MCB) For AC Operation Marked To IS/IEC 60898 (Part 1)Quantity52 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Number of Pole (Hint: "P" - Pole; "PP" - Protected Pole)
- 2 P with 1 PP
- Rated Current (in Ampere)
- 32
- Instantaneous Tripping Current Type
- C
- Rated Short Circuit Capacity (in Ampere)
- 10000
- Provision of Steel Sheet Enclosure for MCB
- Without enclosure
50Miniature Circuit Breakers (MCB) For AC Operation Marked To IS/IEC 60898 (Part 1)Quantity5 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Number of Pole (Hint: "P" - Pole; "PP" - Protected Pole)
- 4 P with 3 PP
- Rated Current (in Ampere)
- 63
- Instantaneous Tripping Current Type
- C
- Rated Short Circuit Capacity (in Ampere)
- 10000
- Provision of Steel Sheet Enclosure for MCB
- Without enclosure
51Miniature Circuit Breakers (MCB) For AC Operation Marked To IS/IEC 60898 (Part 1)Quantity54 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Number of Pole (Hint: "P" - Pole; "PP" - Protected Pole)
- 1 P
- Rated Current (in Ampere)
- 10
- Instantaneous Tripping Current Type
- C
- Rated Short Circuit Capacity (in Ampere)
- 10000
- Provision of Steel Sheet Enclosure for MCB
- Without enclosure
52Non Modular Piano Type Domestic Electrical Sockets ISI Marked To IS 1293Quantity33 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current
- 16.0 (Ampère)
- Number of Pins
- 6 Or higher
- Provision of Safety Shutter in Socket
- With Shutter
- Current Carrying Material
- Brass
- Type of Terminal Connection
- Screw Type Terminal
53Non Modular Piano Type Domestic Electrical Sockets ISI Marked To IS 1293Quantity44 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current
- 6.0 (Ampère)
- Number of Pins
- 3, 6 Or higher
- Provision of Safety Shutter in Socket
- With Shutter
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Current Carrying Material
- Brass
- Type of Terminal Connection
- Screw Type Terminal
54Non Modular Piano Type Domestic Electrical Switches ISI Marked To IS 3854Quantity43 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current
- 6A
- Nature of Switch
- 2 way switch
- Type of Terminal Connection
- Screwless type terminal
- Current Carrying Contact Material
- Copper
55Non Modular Piano Type Domestic Electrical Switches ISI Marked To IS 3854Quantity43 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current
- 6A
- Nature of Switch
- 1 way switch
- Type of Terminal Connection
- Screw type terminal
- Current Carrying Contact Material
- Copper
56Electric Bells And Accessories As Per IS 2268Quantity14 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Product ISI marked
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Type of bell
- Ding Dong type
57Non Modular Piano Type Domestic Electrical Switches ISI Marked To IS 3854Quantity11 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Current
- 6A
- Nature of Switch
- bell push switch
- Type of Terminal Connection
- Screw type terminal
- Current Carrying Contact Material
- Brass
58XLPE Cable For Working Voltage Up To And Including 1.1 KV Marked To IS 7098 (Part 1)Quantity26 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cables suitable for use in mines
- Yes
- Classification of cables for improved fire performace category
- C2 - FR-LSH
- Nominal Area of Conductor (in Sq mm)
- 50
- Number of Cores
- 3.5
- Material of Conductor
- Aluminium
- Construction of the conductor
- Stranded and shaped
- Type of Inner Sheath
- Un-vulcanized rubber
- Type of Cable
- Armoured cable
- Material of Armouring
- Galvanized steel formed wire
- Type of Armouring
- Single wire
- Bis Required
- Yes
59XLPE Cable For Working Voltage Up To And Including 1.1 KV Marked To IS 7098 (Part 1)Quantity22 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cables suitable for use in mines
- No
- Classification of cables for improved fire performace category
- C2 - FR-LSH
- Nominal Area of Conductor (in Sq mm)
- 35
- Number of Cores
- 3.5
- Material of Conductor
- Aluminium
- Construction of the conductor
- Stranded and shaped
- Type of Inner Sheath
- Thermoplastic
- Type of Cable
- Armoured cable
- Material of Armouring
- Galvanized steel formed wire
- Type of Armouring
- Single wire
60XLPE Cable For Working Voltage Up To And Including 1.1 KV Marked To IS 7098 (Part 1)Quantity53 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cables suitable for use in mines
- No
- Classification of cables for improved fire performace category
- C2 - FR-LSH
- Nominal Area of Conductor (in Sq mm)
- 25
- Number of Cores
- 3.5
- Material of Conductor
- Aluminium
- Construction of the conductor
- Stranded and shaped
- Type of Inner Sheath
- Thermoplastic
- Type of Cable
- Armoured cable
- Material of Armouring
- Galvanized steel formed wire
- Type of Armouring
- Single strip
61XLPE Cable For Working Voltage Up To And Including 1.1 KV Marked To IS 7098 (Part 1)Quantity115 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cables suitable for use in mines
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Classification of cables for improved fire performace category
- C1 - FR
- Nominal Area of Conductor (in Sq mm)
- 10
- Number of Cores
- 2
- Material of Conductor
- Aluminium
- Construction of the conductor
- Solid
- Type of Inner Sheath
- Vulcanized rubber
- Type of Cable
- Armoured cable
- Material of Armouring
- Galvanized steel formed wire
- Type of Armouring
- Single wire
62XLPE Cable For Working Voltage Up To And Including 1.1 KV Marked To IS 7098 (Part 1)Quantity62 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cables suitable for use in mines
- No
- Classification of cables for improved fire performace category
- C2 - FR-LSH
- Specification
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement
- Name
- (Allowed Values)
- Nominal Area of Conductor (in Sq mm)
- 25
- Number of Cores
- 4
- Material of Conductor
- Aluminium
- Construction of the conductor
- Stranded and shaped
- Type of Inner Sheath
- Thermoplastic
- Type of Cable
- Armoured cable
- Material of Armouring
- Galvanized steel formed wire
- Type of Armouring
- Single strip
63XLPE Cable For Working Voltage Up To And Including 1.1 KV Marked To IS 7098 (Part 1)Quantity66 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cables suitable for use in mines
- No
- Classification of cables for improved fire performace category
- C2 - FR-LSH
- Nominal Area of Conductor (in Sq mm)
- 16
- Number of Cores
- 2
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Conductor
- Aluminium
- Construction of the conductor
- Stranded
- Type of Inner Sheath
- Thermoplastic
- Type of Cable
- Armoured cable
- Material of Armouring
- Galvanized steel formed wire
- Type of Armouring
- Single strip
64XLPE Cable For Working Voltage Up To And Including 1.1 KV Marked To IS 7098 (Part 1)Quantity78 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cables suitable for use in mines
- No
- Classification of cables for improved fire performace category
- C2 - FR-LSH
- Nominal Area of Conductor (in Sq mm)
- 16
- Number of Cores
- 4
- Material of Conductor
- Aluminium
- Construction of the conductor
- Stranded and shaped
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Type of Inner Sheath
- Un-vulcanized rubber
- Type of Cable
- Armoured cable
- Material of Armouring
- Galvanized round steel wire
- Type of Armouring
- Double strip
65PVC Insulated Unsheathed Cable With Flexible Conductor ISI Marked To IS 694Quantity316 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cable category
- FR-LSH
- Number of Core
- 1
- Nominal Area of Conductor (in Sq mm)
- 6
- Material of conductor
- Plain copper
- Type of Insulation
- Type D
66PVC Insulated Unsheathed Cable With Flexible Conductor ISI Marked To IS 694Quantity861 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cable category
- FR-LSH
- Number of Core
- 1
- Nominal Area of Conductor (in Sq mm)
- 2.5
- Material of conductor
- Plain copper
- Type of Insulation
- Type C (HR)
67PVC Insulated Unsheathed Cable With Flexible Conductor ISI Marked To IS 694Quantity942 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cable category
- FR
- Number of Core
- 1
- Nominal Area of Conductor (in Sq mm)
- 1.5
- Material of conductor
- Plain copper
- Type of Insulation
- Type C (HR)
68PVC Insulated Unsheathed Cable With Flexible Conductor ISI Marked To IS 694Quantity108 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cable category
- FR
- Number of Core
- 1
- Nominal Area of Conductor (in Sq mm)
- 10
- Material of conductor
- Annealled copper
- Type of Insulation
- Type C (HR)
69PVC Insulated Unsheathed Cable With Flexible Conductor ISI Marked To IS 694Quantity329 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Cable category
- FR-LSH
- Number of Core
- 1
- Nominal Area of Conductor (in Sq mm)
- 4
- Material of conductor
- Annealled copper
- Type of Insulation
- Type D
70Flat Cable, Aluminium Conductor With PVC Insulation And Sheathed ISI Marked To IS 694Quantity485 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Category of Cable
- 01
- Type of Insulation
- Type A
- Number of core
- 2
- Outer Sheath
- Type ST 1
- Nominal Area of Conductor (in Sq mm)
- 10.0
- Provision of Tape Between the Cores and Outer Sheath
- Yes
71Flat Cable, Copper Conductor With PVC Insulation And Sheathed ISI Marked To IS 694Quantity284 meterDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Category of Cable
- FR
- Type of Insulation
- Type C (HR)
- Number of Core
- 2
- Conductor Material
- Plain copper
- Nominal Area of Conductor (in Sq.mm)
- 10.0
- Provision of Tape Between the Cores and Outer Sheath
- Yes
72Plasticized PVC Tapes With Non-Thermosetting Adhesive For Electrical Purpose (V2) ISI Marked To IS 7809 (Part 3/ Sec1)Quantity58 rollsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Governing Specification
- As per IS 7809 (Part 3/ Sec1)
- Type
- General Purpose Type (suitable for application at temperature above 0°C, and designated as F- PVCp/90/0/Tp)
- Length of tape in a roll (in metre)
- 25
- Width of tape (in mm) (Tolerance as per clause 6.2.1 of the IS 7809 (part1))
- 25
- Thickness (in mm) (Tolerance ± 0.025 mm)
- 0.125
- Appearance of tape
- Opaque
73Plasticized PVC Tapes With Non-Thermosetting Adhesive For Electrical Purpose (V2) ISI Marked To IS 7809 (Part 3/ Sec1)Quantity59 rollsDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Governing Specification
- As per IS 7809 (Part 3/ Sec1)
- Type
- General Purpose Type (suitable for application at temperature above 0°C, and designated as F- PVCp/90/0/Tp)
- Length of tape in a roll (in metre)
- 25
- Width of tape (in mm) (Tolerance as per clause 6.2.1 of the IS 7809 (part1))
- 20
- Thickness (in mm) (Tolerance ± 0.025 mm)
- 0.125
74Bayonet Lampholders (V2) ISI Marked To IS 1258Quantity26 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated current ( in Amp)
- 2
- Type of bayonet lampholder
- B22d
- Material of lampholder
- Brass
- Method of fixing
- Angular base
75Bayonet Lampholders (V2) ISI Marked To IS 1258Quantity26 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated current ( in Amp)
- 2
- Type of bayonet lampholder
- B22d
- Material of lampholder
- Brass
- Method of fixing
- Batten
76Self Ballasted LED Lamps (LED Bulb) Conforming To IS 16102 (Part 2) (V3)Quantity42 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Wattage (in Watts)
- 12.0
- BEE Star Rating
- 2 Star
- Type of LED Lamp Cap
- B22d
77Self Ballasted LED Lamps (LED Bulb) Conforming To IS 16102 (Part 2) (V3)Quantity37 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Bis Required
- Yes
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Rated Wattage (in Watts)
- 6.0
- BEE Star Rating
- 2 Star
- Type of LED Lamp Cap
- B22d
78Electrical Cable LugsQuantity51 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- E-aluminium
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 300
79Electrical Cable LugsQuantity51 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- E-aluminium
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 185
80Electrical Cable LugsQuantity57 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- E-aluminium
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 120
81Electrical Cable LugsQuantity57 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- E-aluminium
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 150
82Electrical Cable LugsQuantity57 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- E-aluminium
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 95
83Electrical Cable LugsQuantity81 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- E-aluminium
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 70
84Electrical Cable LugsQuantity90 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- E-aluminium
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 35
85Electrical Cable LugsQuantity81 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- E-aluminium
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 50
86Electrical Cable LugsQuantity90 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- E-aluminium
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 16
87Electrical Cable LugsQuantity27 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- Copper
- Shape of Lug
- Round
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 185
88Electrical Cable LugsQuantity29 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- Copper
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 150
89Electrical Cable LugsQuantity40 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- Copper
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 95
90Electrical Cable LugsQuantity41 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- Copper
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 70
91Electrical Cable LugsQuantity55 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- Copper
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 50
92Electrical Cable LugsQuantity78 piecesDelivery30 daysDetailsClose
- Delivery
- 30 days
Specifications & requirements
- Specification Name
- बड के िलए आवPयक अनुमत मूYय /Bid Requirement (Allowed Values)
- Material of Lug [Hint: Products matching all selected values will be displayed; For example, if both 'E-aluminium' and 'Copper' are selected, product that include both options will be shown]
- Copper
- Shape of Lug
- Round
- Suitable Conductor Cross- Sectional Area for Lug (in sq mm)
- 35
No matching items. Try another name, code or schedule.
Tender documents
Bid files and supporting documents, linked directly from GeM.
- Bid documentOpen
Full bid details and conditions
- GeM category specificationOpen
Applies to item 1
- GeM category specificationOpen
Applies to item 2
- GeM category specificationOpen
Applies to item 3
- GeM category specificationOpen
Applies to item 4
- GeM category specificationOpen
Applies to item 5
- GeM category specificationOpen
Applies to item 6
- GeM category specificationOpen
Applies to item 7
- GeM category specificationOpen
Applies to item 8
- GeM category specificationOpen
Applies to item 9
- GeM category specificationOpen
Applies to item 10
- GeM category specificationOpen
Applies to item 11
- GeM category specificationOpen
Applies to item 12
- GeM category specificationOpen
Applies to item 13
- GeM category specificationOpen
Applies to item 14
- GeM category specificationOpen
Applies to item 15
- GeM category specificationOpen
Applies to item 16
- GeM category specificationOpen
Applies to item 17
- GeM category specificationOpen
Applies to item 18
- GeM category specificationOpen
Applies to item 19
- GeM category specificationOpen
Applies to item 20
- GeM category specificationOpen
Applies to item 21
- GeM category specificationOpen
Applies to item 22
- GeM category specificationOpen
Applies to item 23
- GeM category specificationOpen
Applies to item 24
- GeM category specificationOpen
Applies to item 25
- GeM category specificationOpen
Applies to item 26
- GeM category specificationOpen
Applies to item 27
- GeM category specificationOpen
Applies to item 28
- GeM category specificationOpen
Applies to item 29
- GeM category specificationOpen
Applies to item 30
- GeM category specificationOpen
Applies to item 31
- GeM category specificationOpen
Applies to item 32
- GeM category specificationOpen
Applies to item 33
- GeM category specificationOpen
Applies to item 34
- GeM category specificationOpen
Applies to item 35
- GeM category specificationOpen
Applies to item 36
- GeM category specificationOpen
Applies to item 37
- GeM category specificationOpen
Applies to item 38
- GeM category specificationOpen
Applies to item 39
- GeM category specificationOpen
Applies to item 40
- GeM category specificationOpen
Applies to item 41
- GeM category specificationOpen
Applies to item 42
- GeM category specificationOpen
Applies to item 43
- GeM category specificationOpen
Applies to item 44
- GeM category specificationOpen
Applies to item 45
- GeM category specificationOpen
Applies to item 46
- GeM category specificationOpen
Applies to item 47
- GeM category specificationOpen
Applies to item 48
- GeM category specificationOpen
Applies to item 49
- GeM category specificationOpen
Applies to item 50
- GeM category specificationOpen
Applies to item 51
- GeM category specificationOpen
Applies to item 52
- GeM category specificationOpen
Applies to item 53
- GeM category specificationOpen
Applies to item 54
- GeM category specificationOpen
Applies to item 55
- GeM category specificationOpen
Applies to item 56
- GeM category specificationOpen
Applies to item 57
- GeM category specificationOpen
Applies to item 58
- GeM category specificationOpen
Applies to item 59
- GeM category specificationOpen
Applies to item 60
- GeM category specificationOpen
Applies to item 61
- GeM category specificationOpen
Applies to item 62
- GeM category specificationOpen
Applies to item 63
- GeM category specificationOpen
Applies to item 64
- GeM category specificationOpen
Applies to item 65
- GeM category specificationOpen
Applies to item 66
- GeM category specificationOpen
Applies to item 67
- GeM category specificationOpen
Applies to item 68
- GeM category specificationOpen
Applies to item 69
- GeM category specificationOpen
Applies to item 70
- GeM category specificationOpen
Applies to item 71
- GeM category specificationOpen
Applies to item 72
- GeM category specificationOpen
Applies to item 73
- GeM category specificationOpen
Applies to item 74
- GeM category specificationOpen
Applies to item 75
- GeM category specificationOpen
Applies to item 76
- GeM category specificationOpen
Applies to item 77
- GeM category specificationOpen
Applies to item 78
- GeM category specificationOpen
Applies to item 79
- GeM category specificationOpen
Applies to item 80
- GeM category specificationOpen
Applies to item 81
- GeM category specificationOpen
Applies to item 82
- GeM category specificationOpen
Applies to item 83
- GeM category specificationOpen
Applies to item 84
- GeM category specificationOpen
Applies to item 85
- GeM category specificationOpen
Applies to item 86
- GeM category specificationOpen
Applies to item 87
- GeM category specificationOpen
Applies to item 88
- GeM category specificationOpen
Applies to item 89
- GeM category specificationOpen
Applies to item 90
- GeM category specificationOpen
Applies to item 91
- GeM category specificationOpen
Applies to item 92
Policy & contract references
Documents you must submit
- Experience Criteria
- Past Performance
- Bidder Turnover
- Certificate (Requested in ATC)
- OEM Authorization Certificate
- OEM Annual Turnover
Show all 11
- Additional Doc 1 (Requested in ATC)
- Additional Doc 2 (Requested in ATC)
- Additional Doc 3 (Requested in ATC)
- Additional Doc 4 (Requested in ATC)
- Compliance of BoQ specification and supporting document
Eligibility
Experience
3 years
Min. turnover
₹18 L
a year, 3-year average
OEM turnover
₹35 L
Past performance
30%
of the bid quantity
Experience & turnover exemptions
Startups
No exemptionExemption conditions
Exemptions depend on the evidence and conditions specified in the bid.
Preferences & relaxations
- MSE purchase preference
- MII preference
- Class-1/2 local suppliers
- EMD exemption: no
- Inspection required: no
Check each criterion against the tender notice before you bid.
Commercial conditions
- EMD
- ₹109,678
- Performance guarantee
- Not required
- Offer validity
- 30 days
Buyer requirements & conditions
Buyer-added conditions from the bid document.
OPTION CLAUSE: The Purchaser reserves the right to increase or decrease the quantity to be ordered up to 25 percent of bid quantity at the time of placement of contract. The purchaser also reserves the right to increase the ordered quantity up to 25% of the contracted quantity during the currency of the contract at the contracted rates. The delivery period of quantity shall commence from the last date of original delivery order and in cases where option clause is exercised during the extended delivery period the additional time shall commence from the last date of extended delivery period. The additional delivery time shall be (Increased quantity ÷ Original quantity) × Original delivery period (in days), subject to minimum of 30 days. If the original delivery period is less than 30 days, the additional time equals the original delivery period. The Purchaser may extend this calculated delivery duration up to the original delivery period while exercising the option clause. Bidders must comply with these terms.
IMPORTED PRODUCTS: In case of imported products, OEM or Authorized Seller of OEM should have a registered office in India to provide after sales service support in India. The certificate to this effect should be submitted.
Inspection of Stores by Inspection Authority of buyer or their authorised Inspecting officers / empanelled inspection agency or their representatives An independent third party Professional Inspection Body can help buyer in mitigating buyer's risk with pre-dispatch/post-dispatch inspection in order to ensure that equipment, components , solutions and documentation conform to contractual requirements. If an institutional buyer like Defense , Railways and MHA etc desires to appoint / nominate their own inspection authority / empanelled inspection agency for inspection of stores to be supplied against the contract , buyer can select this clause indicating cost of inspection in term of percentage which is 0 %. As per the contractual provisions / law , the buyer has a right before payment or acceptance to inspect goods at any reasonable place as indicated in contract and time and in any reasonable manner. When the seller is required or authorized to send the goods to the buyer, the inspection may be after their arrival. Expenses of inspection should be borne by the buyer but may be recovered from the seller if the goods do not conform to contractual specification and are rejected. Initially seller may pay for inspection charges as applicable and get the same reimbursed from buyer if store complies to contractual specification etc , on production of payment receipt issued by inspection agency as applicable. Seller/OEM shall send a notice in writing / e-mail to the Inspecting officer / inspection agency specifying the place where inspection is offered and the Inspecting officer shall on receipt of such notice notify to the seller the date and time when the stores would be inspected. The seller shall, at his own expenses, afford to the Inspecting officer , all reasonable facilities and such accommodation as may be necessary for satisfying himself that the stores are being and or have been manufactured in accordance with the technical particulars governing the supply . The decision of the purchaser/inspection authority regarding acceptance / rejection of consignment shall be final and binding on the seller. The Seller shall provide, without any extra charge, all materials, tools, labour and assistance of every kind which the Inspecting officer may demand of him for any test, and examination, other than special or independent test, which he shall require to be made on the seller's premises and the seller shall bear and pay all costs attendant thereon. The seller shall also provide , and deliver for test, free of charge, at such place other than his premises as the Inspecting officer may specify such material or stores as he may require for tests for which seller does not have the facilities or for special/ independent tests. In the event of rejection of stores or any part thereof by the Inspecting officer basis testing outside owing to lack of test facility at sellers premises ,the seller shall, on demand, pay to the buyer the costs incurred in the inspection and/or test. Cost of test shall be assessed at the rate charged by the Laboratory to private persons for similar work. Inspector shall have the right to put all the stores or materials forming part of the same or any part thereof to such tests as he may like fit and proper as per QAP/governing specification . The seller shall not be entitled to object on any ground whatsoever to the method of testing adopted by the Inspecting officer .. Unless otherwise provided for in the contract, the quantity of the stores or materials expended in test will be borne by seller . Inspecting officer is the Final Authority to Certify Performance / accept the consignment . The Inspecting officer’s decision as regards the rejection shall be final and binding on the seller. The seller shall if so required at his own expense mark or permit the Inspecing officer to mark all the approved stores with a recognised Government or purchaser's mark.
Bidders can also submit the EMD with Fixed Deposit Receipt made out or pledged in the name of A/C COMMANDER WORKS ENGINEER UDHAMPUR PAYABLE AT SBI UDHAMPUR J&K . The bank should certify on it that the deposit can be withdrawn only on the demand or with the sanction of the pledgee. For release of EMD, the FDR will be released in the favour of the bidder by the Buyer after making endorsement on the back of the FDR duly signed and stamped along with covering letter. Bidder has to upload scanned copy/ proof of the FDR along with bid and has to ensure delivery of hardcopy to the Buyer within 5 days of Bid End date/ Bid Opening date
Scope of supply (Bid price to include all cost components) : Only supply of Goods
Bidder's offer is liable to be rejected if they don't upload any of the certificates / documents sought in the Bid document, ATC and Corrigendum if any.
ISO 9001: The bidder or the OEM of the offered products must have ISO 9001 certification.
Material Test Certificate Should Be Sent Along with The Supply. The Material Will Be Checked by Buyer’s Lab & the Results of the Lab will be the Sole Criteria for Acceptance of the Item.
Buyer Added text based ATC clauses UPLOAD DECLARATION/ CERTIFICATES/ UNDERTAKINGS ON IP ADDRESS, CARTEL BIDDING, SISTER CONCE RN FIRMS, MI.I. UNDERTAKING, BIDDER FINANCIAL STANDING etc:-
- (1)We accept all the terms & conditions of the bid.
- (2)We declare that we have utilized our own resources of electronic media f or the bid process. We have u tilized outside sources of friends / relatives / cyber café when our resources failed/ malfunctioned. As such, we are not involved in any cartel bidding with other bidders if any participated.
- (3)We confirm that any of our sister concern firms have not participated in the bid (i.e. Same business pa rtner shall not be repeated in more than one firm.)
- (4)We confirm that our firm will supply only the products having local content adhering to existing M.I.I. p olicies of Govt of India
- (5)We are not under liquidation, court receivership or similar proceedings and not bankrupt. BIDDER SHALL UPLOAD THE FOLLOWING DOCUMENTS ALONG WITH THEIR BID FOR VENDOR CODE CREATI ON WHICH OTHERWISE RESULT DELAYS IN PAYMENTS:- A). Copy of PAN Card. B). Copy of GSTIN. C). Copy of Cancelled Cheque.
- D.Copy of EFT Mandate Duly Certified By Bank. UPLOAD M.I.I. CERTIFICATE FROM OEMs OF MAKES QUOTED OUT OF THE MAKES MENTIONED, DULY SHO WED OF CLASS & PERCENTAGE OF LOCAL CONTENT IN THE LIGHT OF GOVERNMENT PUBLIC PROCUREMEN T (PREFERENCE TO MAKE IN INDIA), ORDER DATED 2017, CONSEQUENT ORDER N O. P‐45021/2/2017‐PP (B E‐II) DATED 04.06.2020 &16.09.2020 AND SUBSEQUENT CLARIFICATION NO P‐45021/102/2019‐BE‐II‐PART( 1) (E‐50310) DATED 04.03.2021 INCLUDING OM NO. F.1/4/2021- PPD DATED 18 MAY 2023. THE MATERIALS SUPPLIED SHALL BE INSPECTED BY A BOARD OF OFFICERS BY THE DEPARTMENT AT CONSI GNEE END WITH RESPECT TO THE SPECIFICATIONS AND IS CODES. WHEREVER MENTIO NED AS “ISI MARK ED”, THE STORES SHALL BE SUPPLIED ACCORDINGLY. THE GENERAL ENGINEERI NG PRACTICE SHALL BE A PPLIED FOR ITEMS HAVING SHORT FALL OF SPECIFICATIONS. THE MATER IAL WILL BE REJECTED IN FULL IF SPECIFICATIONS ARE NOT CONFORMING OR NOT AS PER IS CODES OR BID SPECIFICATION. WARRANTY CERTIFICATES FOR SPECIFIED PERIODS AS PER THE BID ITEMS ON BIDDER LETTER HE AD, VALI D TEST CERTIFICATES FROM GOVT LABS OR ANY GOVT ACCREDITED LABS AT THE DISCRETION OF OEM OR IN-HOUSE LABS ETC AS PER GeM NORMS, BIS LICENCE FOR THE QUOTED ITEMS, OUT OF MAKES MENTI ONED IN ATC, TO BE SUBMITTED TO THE CONSIGNEE ON DEMAND ALONGWITH THE MATERIALS AS APPLIC ABLE WHEREVER “ISI MARKED” IS SPECIFIED SO AS TO REVERT TO OEM IN CASE OF NON-COMPLIANCE BY BIDDER OR OTHERWISE WITH ANY DISCREPANCY ON GeM PORTAL OR CLAIM BY ANY OTHER BIDDER BEFO RE/ AFTER SUPPLY BY REFERRING CASE TO OEM BASED ON BID AUTHORISATION ISSUED BY OEM. THE MIN OR ERRORS, IF ANY PUBLISHED IN THE CATALOGUES ON GeM PORTAL FOR NON-SELECTABLE PARAMENTE RS/ SPECIFICTIONS, IF FOUND AT PA R COMMONLY WITH ALL BIDDER PARTICIPANTS, WILL BE IGNORED W HILE ASCERTAINING FOR QUALIFICATION CRITERION. IN SUCH CASES, IF ANY BIDDER CLAIMS/ REPRESENT S, OEMs OF QUOTED PRODUCTS WILL BE APPROACHED FOR CLARIFICATION & ASSUANCE OF SUPPLY FRO M OEMs FOR ENSURING PROPER PRODUCTS AS PER GOLDEN & GREY SPECIFICATIONS/ PARAMETER. UPLOAD PAST PERFORMANCE/ EXPERIENCE DOCUMENTS IN THE FORM OF ANY GOVT PURCHASE ORDERS OR RESPECTIVE GeM CRACs OR GOVT COMPLETION REPORTS OR GOVT WORK COMPLETION CERTIFICATES ALONG WITH THE WORK ORDERS FOR THE PRIMARY CATEGORY GOODS AS MENTIONED IN THE BID AND A LSO IN THE SIMILAR MATERIAL CUM TECHNICAL FUNCTIONAL GOODS OF REPETITIVE CATEGORY NATURE U NDER VARIOUS QUADRANTS ON GeM PORTAL AS SELECTED IN THE BID. UPLOAD C.A. AUDITED ANNUAL TURNOVER OF OEM(s) & ALSO OF BIDDER FOR 03 LATEST CONS ECUTIVE FINANCIAL YEARS AS SOUGHT. UPLOAD OEM’S BID SPECIFIC AUTHORIZATION ON OEM’S LETTER HEAD OF QUOTED MAKES OUT OF MAKE S MENTIONED IN THE INSTANT BID SO AS TO CONTACT & ALSO TO ENTWINE OEMs IN CA SE OF NON-RESP ONSE BY BIDDER AFTER SUPPLY BEFORE EXPIRY OF WARRANTY PERIODS AND AL SO SEEK ANY SORT OF C LARIFICATIONS OF PRODUCTS SUPPLIED. WHEREVER MAKES NOT SPECIFIED, BIDDER MUST QUOTE FOR ITEMS CONFORMING TO THE SPECI FICATIO NS/ ISI NORMS ETC. AS MENTIONED IN THE BID. WHILE QUOTING THE PRODUCTS, BIDDER SHALL MENTIO N SINGLE MAKE & MODEL IN THE GIVEN FIELDS AVAILABLE IN THE BOQ. QUOTING A BOVE MULTIPLE MAKE S OR MENTIONING WORDS LIKE “EQUIVALENT OR SIMILAR” WILL FORM BASI S DISQUALIFICATION OF THE BIDDER. EMD MUST REACH THIS OFFICE BEFORE THE BID OPENING DATE & TIME IN TOKEN OF UPLOADED EMD EXT RACT, FAILING WHICH BIDDER WILL BE DISQUALIFIED. THE EMD WILL BE RETURNED AS PER GTC STIPULA TIONS. SUBMISSION OF ePBG AFTER THE DATE OF EXECUTION OF ORDER WILL BE TREATED AS DELAY IN E XECUTION OF ORDER AND SUITABLE LIQUIDATED DAMAGE, AS MENTIONED IN GTC, SHALL BE APPLIED. IN CASE DIFFERENT GOLDEN TECHNICAL PARAMETERS ARE ERRONEOUSLY PUBLISHED AGAINST SAME SP ECIFICATION IN THE BID IN THE SAME CATALOGUE DUE TO ANY TECHNICAL REASONS/ ER RORS ON WEB P ORTAL, THE HIGHER PARAMETER SHALL BE CONSIDERED FOR QUOTING. NO PART PAYMENTS ARE ENTERTAINED EVEN FOR THE CASES WARRANTING SUPPLY OF SAMPLE. IN CASE ABOVE SIMILAR PROVISION MENTIONED AT ANY LOCATION OF THE BID, ABOVE PROVISIONS WILL SUPERSEDE EXCLUDING CERTAIN GTC CONDITIONS. THE FOLLOWING BRANDS ARE TO BE CONSIDERED IN TECH EVALUATION OF BID JOINT KIT :- DENSON, 3M, RAYCHEM, M SEAL, CABSEAL MCB & MCCB - LEGRAND, SIEMENS, L&T, HAVELLS, SCHNEIDER, ANCHOR FOR SWITCH SOCKET :- PHILIPS, BAJAJ, HAVELLS, ANCHOR, SEIMENS STREET LIGHT :- PHILIPS, WIPRO, CROMPTON, HAVELLS, SURYA FOR PVC FLAT CABLE :- ABB, LEGRAND, KEI, FINOLEX, GRANDLAY, ANCHOR, HAVELLS XLPE CABLE :- FINOLEX, KEI, POLYCAB, GRANDLAY, HAVELLS LUGS :- DOLLAR, DOWELLS GARDEN LIGHT AND BULKHEAD :- HAVELLS,WIPRO, BAJAJ, SURYA IF FIRM IS NOT SUPPLIED PRODUCT AS PER GEM ORDER/SPECIF, THE SAME MAY BE REJECTED OR REPLAC E AT THE TIME OF DELIVERY BY CONSIGNEE WITH APPROVAL OF BUYER. NOTE:- 1. CWE UDH DEC 2026 SHOULD BE EMBOSSED ON EACH ITEM (LED BATTEN, STREET LIGHT, FLO OD LIGHT, MCB, MCCB, GARDEN LIGHT, BULKHEAD, LED LAMP) BEFORE DELIVERING AT CONSIGNEE LOCATION. THE ITEMS WHICH DO NOT HAVE THE SAME EMBOSSING WILL BE REJECTED BY THE BOB
- 2.BIDDER SHOULD BE SUBMITTING CERTIFICATE THAT CWE UDH DEC 2026 IS EMBOSSING ON EACH ITEM (LED BATTEN, STREET LIGHT, FLOOD LIGHT, MCB, MCCB, GARDEN LIGHT, BULKHEAD, LED LAMP), IF CERT I S NOT SUBMITTED BY BIDDER BEFORE OPENING OF BID THEN BUYER DISQUALIFIED THE BIDDER IN TECHN ICAL EVALUATION. .
- 10.Turnover Bidder Turn Over Criteria: The minimum average annual financial turnover of the bidder during the last three years, ending on 31st March of the previous financial year, should be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant / Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution / incorporation of the bidder is less than 3 year old, the average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria.
- 11.Turnover OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years, ending on 31st March of the previous financial year, should be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant / Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution / incorporation of the OEM is less than 3 year old, the average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. In case of bunch bids, the OEM of CATEGORY RELATED TO primary product having highest bid value should meet this criterion.
Warranty period of the supplied products shall be as given in specifications from the date of final acceptance of goods or after completion of installation, commissioning & testing of goods (if included in the scope of supply), at consignee location. OEM Warranty certificates must be submitted by Successful Bidder at the time of delivery of Goods. The seller should guarantee the rectification of goods in case of any break down during the guarantee period. Seller should have well established Installation, Commissioning, Training, Troubleshooting and Maintenance Service group in INDIA for attending the after sales service. Details of Service Centres near consignee destinations are to be uploaded along with the bid.
Similar open tenders
Soonest first- TodayclosesMoulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2), Miniature Circu…Ministry of Defence · Closes 16 Oct 2026
- 1 dayleftNon Modular Piano Type Domestic Electrical Switches ISI Marked To IS 3854, Non Modular Pi…Ministry of Defence · Closes 17 Oct 2026
- 3 daysleftCopper Alloy Taps/Stop Valves (V2) Conforming To IS 8931, LED Luminaire For Road And Stre…Ministry of Defence · Closes 19 Oct 2026
- 3 daysleftRotational Moulded Polyethylene Water Storage Tanks (V3) Conforming To IS 12701, PLASTIC…Ministry of Defence · Closes 19 Oct 2026
- 3 daysleftMoulded Case Circuit Breakers (MCCB) Conforming To IS/IEC 60947 (Part 2), Miniature Circu…Ministry of Defence · Closes 19 Oct 2026
- 8 daysleftMiniature Circuit Breakers (MCB) For AC Operation Marked To IS/IEC 60898 (Part 1), Moulde…Ministry of Defence · Closes 24 Oct 2026
- 8 daysleftXLPE Cable For Working Voltage Up To And Including 1.1 KV Marked To IS 7098 (Part 1), LED…Ministry of Defence · Closes 24 Oct 2026
- 10 daysleftElectric Bells And Accessories As Per IS 2268, Plasticized PVC Tapes With Non-Thermosetti…Ministry of Defence · Closes 26 Oct 2026
Search similar in the explorerFind this tender in the explorer